Re: [RFR 2/2] drm/panel: Add simple panel support

2 messages, 2 authors, 2013-10-17 · open the first message on its own page

Re: [RFR 2/2] drm/panel: Add simple panel support

From: Laurent Pinchart <hidden>
Date: 2013-10-17 12:14:45

On Thursday 17 October 2013 13:41:40 Thierry Reding wrote:
On Thu, Oct 17, 2013 at 01:02:38PM +0200, Laurent Pinchart wrote:
quoted
On Thursday 17 October 2013 10:53:43 Thierry Reding wrote:
[...]
quoted
CDF needs to model video pipelines that can be more complex than just a
display controller with a single output connected to a panel with a single
input. For that reason the DT bindings need to describe connections in a
generic enough way. The above DT fragment might be slightly more complex
than one would expect when thinking about the really simple case only,
but it's nowhere near overly complex in my opinion.

Please note that, when a device has as single port, the ports node can be
omitted, and the port doesn't need to be numbered. You would then end up
with> 
 	dc: display-controller {
		port {
			remote-endpoint = <&panel>;
 		};
 	};
 	
 	panel: panel {
 		port {
 			remote-endpoint = <&dc>;
 		};
 	};

I don't think there's a way to simplify it further.
That binding looks completely inconsistent to me. If we can write it either
using a ports node with port@X subnodes, in my opinion we can equally well
just use a unidirectional link for the case where we don't need the link
back from the panel to the output. Where's the difference?

Consider for example the case where an LVDS panel is connected to a simple
LVDS output. For what possible reason would the panel need to access the
output?
The point is that the video pipeline must be described in DT. Having a per-
device way to represent connections would be a nightmare to support from an 
implementation point of view, hence the need for a generic way to describe 
them.
quoted
quoted
quoted
I also plan to specify video bus parameters in DT for CDF, but this
hasn't been finalized yet.
That effectively blocks any of the code that I've been working on until
CDF has been merged. It's been discussed for over a year now, and there
has even been significant pushback on using CDF in DRM, so even if CDF
is eventually merged, that will still leave DRM with no way to turn on
a simple panel.
I'm probably even more concerned about the long time all this took and
will still take than you are, sincerely. I'm obviously to blame for not
being able to explain the problems and solutions correctly, as I see no
way why people would push back if they realized that the other solutions
that have been proposed, far from being future-proof, won't even be
present-proof. We would be shooting ourselves in the foot, but what can I
do when too many people want to do so ?
I'm curious why you think this current proposal isn't present-proof. All
three panels that I've tested with work with this proposal currently and
I'm convinced that many more setups can be covered using something as
simple as this.
My apologies for not being clear enough. I wasn't implying that your proposal 
isn't present-proof, I was talking about the counter-proposals that have been 
made in reaction to CDF.
quoted
I'll still keep trying of course, but not for years.I have yet to
see someone proposing a viable solution to share drivers between DRM and
V4L2, which is a real pressing requirement, partly due to DT.
Yeah... I still don't get that side of the argument. Why exactly do we need
to share the drivers again?
Think about a scaler IP in a SoC or FPGA, with one instance used in a camera 
capture pipeline, supported by a V4L2 driver, and one instance used in a video 
output pipeline, supported by a DRM driver. We want a single driver for that 
IP core. Same story for video encoders.
If we really need to support display output within V4L2, shouldn't we
instead improve interoperability between the two and use DRM/KMS exclusively
for the output part? Then the problem of having to share drivers between
subsystems goes away and we'll actually be using the right subsystem for the
right job at hand.
In the long term we definitely should improve interoperability between the 
two. I'd go further than that, having one API for video capture and one API 
for video output doesn't make much sense, except for historical reasons.
Of course none of that is relevant to the topic of DT bindings, which is
what we should probably be concentrating on.
It actually is. Given that DT bindings must describe hardware, the scaler (or 
encoder, or other entity) would use the same bindings regardless of the Linux 
subsystem that will be involved. We thus need to make sure the bindings will 
be usable on both sides.
Nobody's been able to come up with a valid reason why the proposed binding
is broken. It works for the tested devices (likely many more as well) and I
don't forsee why it can't be future-proof. Why would it suddenly need to
change? And even if it needed to change, why would the changes be backwards-
incompatible rather than simply additional features that don't impact
existing users?
quoted
Regarding the use of CDF in DRM, please note that it will be optional for
drivers to switch to the new framework. Nothing should hopefully require
existing drivers to be converted, drivers that want to make use of CDF to
support panels will be welcome to do so, but they big DRM drivers for
desktop GPUs won't be affected.
I'm not at all opposed to the idea of CDF or the problems it tries to
address. I don't think it necessarily should be a separate framework for
reasons explained earlier. But even if it were to end up in a separate
framework there's absolutely nothing preventing us from adding a DRM panel
driver that hooks into CDF as a "backend" of sorts for panels that require
something more complex than the simple-panel binding.
Once again it's not about panel having complex needs, but more about using 
simple panels in complex pipelines. I'm fine with the drm_panel 
infrastructure, what I would like is DT bindings that describe connections in 
a more future-proof way. The rest is fine.
quoted
quoted
I keep wondering why we absolutely must have compatibility between CDF
and this simple panel binding. DT content is supposed to concern itself
with the description of hardware only. What about the following isn't an
accurate description of the panel hardware?

	panel: panel {
		compatible = "cptt,claa101wb01";
		
		power-supply = <&vdd_pnl_reg>;
		enable-gpios = <&gpio 90 0>;
		
		backlight = <&backlight>;
	};
	
	dsi-controller {
		panel = <&panel>;
	};

Note how the above is also not incompatible with anything that the CDF
(to be) mandates, so it could easily be extended with any nodes or
properties that CDF needs to work properly without breaking backwards-
compatibility.
As mentioned above, CDF needs to describe more complex pipelines. To make
the driver life as simple as possible the core code will handle the
pipeline description in the DT bindings, and it does require it to be
generic enough. You can of course describe connections in various ways
depending on the hardware, which would make the DT-related code
needlessly overcomplex. One of the issue with the above description is
that there's no way to go from the panel to the display controller, which
might be a show stopper in the future when code requires that. A
workaround would be to look through the whole DT for the reverse link,
which would be pretty inefficient.
But that's precisely the point. Why would we need to go back from the panel
to the display controller? Especially for dumb panels that can't or don't
have to be configured in any way. Even if they needed some sort of setup,
why can't that be done from the display controller/output.

Even given a setup where a DSI controller needs to write some registers in a
panel upon initialization, I don't see why the reverse connection needs to
be described. The fact alone that an output dereferences a panel's phandle
should be enough to connect both of them and have any panel driver use the
DSI controller that it's been attached to for the programming.

That's very much analogous to how I2C works. There are no connections back
to the I2C master from the slaves. Yet each I2C client driver manages to use
the services provided by the I2C master to perform transactions on the I2C
bus. In a similar way the DSI controller is the bus master that talks to DSI
panels. DSI panels don't actively talk to the DSI controller.
It's all about modeling video pipeline graphs in DT. To be able to walk the 
graph we need to describe connections. Not having bidirectional information 
means that we restrict the points at which we can start walking the graph, 
potentially making our life much more difficult in the future.

What's so wrong about adding a port node and link information to the panel DT 
node ? It describe what's there: the panel has one input, why not make that 
explicit ?
quoted
quoted
quoted
quoted
+static void panel_simple_enable(struct drm_panel *panel)
+{
+	struct panel_simple *p = to_panel_simple(panel);
+	int err;
+
+	if (p->enabled)
+		return;
+
+	err = regulator_enable(p->supply);
+	if (err < 0)
+		dev_err(panel->dev, "failed to enable supply: %d\n", err);
Is that really a non-fatal error ? Shouldn't the enable operation
return an int ?
There's no way to propagate this in DRM, so why go through the trouble
of returning the error? Furthermore, there's nothing that the caller
could do to remedy the situation anyway.
That's a DRM issue, which could be fixed. While the caller can't remedy
the situation, it should at least report the error to the application
instead of silently ignoring it.
Perhaps. It's not really relevant to the discussion and can always be
fixed in a subsequent patch.
Most things can be fixed by a subsequent patch, that's not a good enough 
reason not to address the known problems before pushing the code to mainline 
(to clarify my point of view, there's no need to fix DRM to use the return 
value before pushing this patch set to mainline, but I'd like a v2 with an int 
return value).
quoted
quoted
quoted
quoted
+static const struct drm_display_mode auo_b101aw03_mode = {
+	.clock = 51450,
+	.hdisplay = 1024,
+	.hsync_start = 1024 + 156,
+	.hsync_end = 1024 + 156 + 8,
+	.htotal = 1024 + 156 + 8 + 156,
+	.vdisplay = 600,
+	.vsync_start = 600 + 16,
+	.vsync_end = 600 + 16 + 6,
+	.vtotal = 600 + 16 + 6 + 16,
+	.vrefresh = 60,
+};
Instead of hardcoding the modes in the driver, which would then
require to be updated for every new simple panel model (and we know
there are lots of them), why don't you specify the modes in the panel
DT node ? The simple panel driver would then become much more generic.
It would also allow board designers to tweak h/v sync timings
depending on the system requirements.
Sigh... we keep second-guessing ourselves. Back at the time when power
sequences were designed (and NAKed at the last minute), we all decided
that the right thing to do would be to use specific compatible values
for individual panels, because that would allow us to encode the power
sequencing within the driver. And when we already have the panel model
encoded in the compatible value, we might just as well encode the mode
within the driver for that panel. Otherwise we'll have to keep adding
the same mode timings for every board that uses the same panel.

I do agree though that it might be useful to tweak the mode in case the
default one doesn't work. How about we provide a means to override the
mode encoded in the driver using one specified in the DT? That's
obviously a backwards-compatible change, so it could be added if or when
it becomes necessary.
I share Tomi's point of view here. Your three panels use the same power
sequence, so I believe we should have a generic panel compatible string
that would use modes described in DT for the common case. Only if a panel
required something more complex which can't (or which could, but won't
for any reason) accurately be described in DT would you need to extend
the driver.
I don't see the point quite frankly. You seem to be assuming that every
panel will only be used in a single board.
No, but in practice that's often the case, at least for boards with .dts files 
in the mainline kernel.
However what you're proposing will require the mode timings to be repeated
in every board's DT file, if the same panel is ever used on more than a
single board.
Is that a problem ? You could #include a .dtsi for the panel that would 
specify the video mode if you want to avoid multiple copies.

-- 
Regards,

Laurent Pinchart

Re: [RFR 2/2] drm/panel: Add simple panel support

From: Thierry Reding <hidden>
Date: 2013-10-17 12:46:20

On Thu, Oct 17, 2013 at 02:14:45PM +0200, Laurent Pinchart wrote:
On Thursday 17 October 2013 13:41:40 Thierry Reding wrote:
quoted
On Thu, Oct 17, 2013 at 01:02:38PM +0200, Laurent Pinchart wrote:
quoted
On Thursday 17 October 2013 10:53:43 Thierry Reding wrote:
[...]
quoted
CDF needs to model video pipelines that can be more complex than just a
display controller with a single output connected to a panel with a single
input. For that reason the DT bindings need to describe connections in a
generic enough way. The above DT fragment might be slightly more complex
than one would expect when thinking about the really simple case only,
but it's nowhere near overly complex in my opinion.

Please note that, when a device has as single port, the ports node can be
omitted, and the port doesn't need to be numbered. You would then end up
with> 
 	dc: display-controller {
		port {
			remote-endpoint = <&panel>;
 		};
 	};
 	
 	panel: panel {
 		port {
 			remote-endpoint = <&dc>;
 		};
 	};

I don't think there's a way to simplify it further.
That binding looks completely inconsistent to me. If we can write it either
using a ports node with port@X subnodes, in my opinion we can equally well
just use a unidirectional link for the case where we don't need the link
back from the panel to the output. Where's the difference?

Consider for example the case where an LVDS panel is connected to a simple
LVDS output. For what possible reason would the panel need to access the
output?
The point is that the video pipeline must be described in DT. Having a per-
device way to represent connections would be a nightmare to support from an 
implementation point of view, hence the need for a generic way to describe 
them.
Okay, so we're back to the need to describe pipelines in DT. At the risk
of sounding selfish: I don't care about pipelines. I just want us to
settle on a way to represent a dumb panel in DT so that it can be
enabled when it needs to. Furthermore I don't have any hardware that
exhibits any of these "advanced" features, so I'm totally unqualified to
work on any of this.

Can we please try to be a little pragmatic here and solve one problem at
a time? I am aware that solving this for panels may require some amount
of foresight, but let's not try to solve everything at once at the risk
of not getting anything done at all.
quoted
quoted
I'll still keep trying of course, but not for years.I have yet to
see someone proposing a viable solution to share drivers between DRM and
V4L2, which is a real pressing requirement, partly due to DT.
Yeah... I still don't get that side of the argument. Why exactly do we need
to share the drivers again?
Think about a scaler IP in a SoC or FPGA, with one instance used in a camera 
capture pipeline, supported by a V4L2 driver, and one instance used in a video 
output pipeline, supported by a DRM driver. We want a single driver for that 
IP core. Same story for video encoders.
Yes, I see. This doesn't immediately concern the simple panel problem
that I'm trying to solve, so perhaps we can have a separate discussion
about it. Perhaps this would more easily be solved by providing some
sort of helper library for the lower level control of the device and
wrapping that with V4L2 or DRM APIs.
quoted
If we really need to support display output within V4L2, shouldn't we
instead improve interoperability between the two and use DRM/KMS exclusively
for the output part? Then the problem of having to share drivers between
subsystems goes away and we'll actually be using the right subsystem for the
right job at hand.
In the long term we definitely should improve interoperability between the 
two. I'd go further than that, having one API for video capture and one API 
for video output doesn't make much sense, except for historical reasons.
Having two separate subsystems has worked out pretty well so far. In my
opinion having strong boundaries between subsystems helps with design.
quoted
Of course none of that is relevant to the topic of DT bindings, which is
what we should probably be concentrating on.
It actually is. Given that DT bindings must describe hardware, the scaler (or 
encoder, or other entity) would use the same bindings regardless of the Linux 
subsystem that will be involved. We thus need to make sure the bindings will 
be usable on both sides.
Perhaps a single driver could expose both interfaces?
quoted
I'm not at all opposed to the idea of CDF or the problems it tries to
address. I don't think it necessarily should be a separate framework for
reasons explained earlier. But even if it were to end up in a separate
framework there's absolutely nothing preventing us from adding a DRM panel
driver that hooks into CDF as a "backend" of sorts for panels that require
something more complex than the simple-panel binding.
Once again it's not about panel having complex needs, but more about using 
simple panels in complex pipelines. I'm fine with the drm_panel 
infrastructure, what I would like is DT bindings that describe connections in 
a more future-proof way. The rest is fine.
And I've already said elsewhere that the bindings in their current form
are easily extensible to cater for the needs of CDF.
quoted
But that's precisely the point. Why would we need to go back from the panel
to the display controller? Especially for dumb panels that can't or don't
have to be configured in any way. Even if they needed some sort of setup,
why can't that be done from the display controller/output.

Even given a setup where a DSI controller needs to write some registers in a
panel upon initialization, I don't see why the reverse connection needs to
be described. The fact alone that an output dereferences a panel's phandle
should be enough to connect both of them and have any panel driver use the
DSI controller that it's been attached to for the programming.

That's very much analogous to how I2C works. There are no connections back
to the I2C master from the slaves. Yet each I2C client driver manages to use
the services provided by the I2C master to perform transactions on the I2C
bus. In a similar way the DSI controller is the bus master that talks to DSI
panels. DSI panels don't actively talk to the DSI controller.
It's all about modeling video pipeline graphs in DT. To be able to walk the 
graph we need to describe connections. Not having bidirectional information 
means that we restrict the points at which we can start walking the graph, 
potentially making our life much more difficult in the future.

What's so wrong about adding a port node and link information to the panel DT 
node ? It describe what's there: the panel has one input, why not make that 
explicit ?
What's wrong with it is that there's no way to verify the soundness of
the design by means of a full implementation because we're missing the
majority of the pieces. Just putting the nodes into DT to provide some
imaginary future-proofness isn't helpful either. Without any code that
actually uses them they are useless.

And again, why should we add them right away (while not needed) when
they can easily be added in a backwards-compatible manner at some later
point when there's actually any use for them and they can actually be
tested in some larger framework?
quoted
quoted
quoted
quoted
quoted
+static void panel_simple_enable(struct drm_panel *panel)
+{
+	struct panel_simple *p = to_panel_simple(panel);
+	int err;
+
+	if (p->enabled)
+		return;
+
+	err = regulator_enable(p->supply);
+	if (err < 0)
+		dev_err(panel->dev, "failed to enable supply: %d\n", err);
Is that really a non-fatal error ? Shouldn't the enable operation
return an int ?
There's no way to propagate this in DRM, so why go through the trouble
of returning the error? Furthermore, there's nothing that the caller
could do to remedy the situation anyway.
That's a DRM issue, which could be fixed. While the caller can't remedy
the situation, it should at least report the error to the application
instead of silently ignoring it.
Perhaps. It's not really relevant to the discussion and can always be
fixed in a subsequent patch.
Most things can be fixed by a subsequent patch, that's not a good enough 
reason not to address the known problems before pushing the code to mainline 
(to clarify my point of view, there's no need to fix DRM to use the return 
value before pushing this patch set to mainline, but I'd like a v2 with an int 
return value).
Why? What's the use of returning an error if you know up front that it
can't be used? This should be changed if or when we "fix" DRM to
propagate errors.
quoted
quoted
quoted
quoted
Instead of hardcoding the modes in the driver, which would then
require to be updated for every new simple panel model (and we know
there are lots of them), why don't you specify the modes in the panel
DT node ? The simple panel driver would then become much more generic.
It would also allow board designers to tweak h/v sync timings
depending on the system requirements.
Sigh... we keep second-guessing ourselves. Back at the time when power
sequences were designed (and NAKed at the last minute), we all decided
that the right thing to do would be to use specific compatible values
for individual panels, because that would allow us to encode the power
sequencing within the driver. And when we already have the panel model
encoded in the compatible value, we might just as well encode the mode
within the driver for that panel. Otherwise we'll have to keep adding
the same mode timings for every board that uses the same panel.

I do agree though that it might be useful to tweak the mode in case the
default one doesn't work. How about we provide a means to override the
mode encoded in the driver using one specified in the DT? That's
obviously a backwards-compatible change, so it could be added if or when
it becomes necessary.
I share Tomi's point of view here. Your three panels use the same power
sequence, so I believe we should have a generic panel compatible string
that would use modes described in DT for the common case. Only if a panel
required something more complex which can't (or which could, but won't
for any reason) accurately be described in DT would you need to extend
the driver.
I don't see the point quite frankly. You seem to be assuming that every
panel will only be used in a single board.
No, but in practice that's often the case, at least for boards with .dts files 
in the mainline kernel.
quoted
However what you're proposing will require the mode timings to be repeated
in every board's DT file, if the same panel is ever used on more than a
single board.
Is that a problem ? You could #include a .dtsi for the panel that would 
specify the video mode if you want to avoid multiple copies.
Yes, I don't think it's desirable to duplicate data needlessly in DT. It
also makes the binding more difficult to use. If I know that the panel
is one supported by the simple-panel binding, I can just go and add the
right compatible value without having to bother looking up the mode
timings and duplicating them. That way DT writers get to concern
themselves only with the variable data.

Thierry