Re: [PATCH 1/7] x86/Documentation: Describe the Intel Hardware Feedback Interface
From: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Date: 2021-11-30 10:20:27
Also in:
linux-pm, lkml
Hi Daniel, On Tue, 2021-11-30 at 10:24 +0100, Daniel Lezcano wrote:
Hi Ricardo,quoted
[...]
quoted
+The Hardware Feedback Interface +------------------------------- + +The Hardware Feedback Interface provides to the operating system information +about the performance and energy efficiency of each CPU in the system. Each +capability is given as a unit-less quantity in the range [0-255]. Higher values +indicate higher capability. Energy efficiency and performance are reported in +separate capabilities.Are they linked together (eg. higher energy efficiency => lower performance)?
Generally true. But for some workload and condition higher energy efficient point doesn't mean lower performance.
quoted
+These capabilities may change at runtime as a result of changes in the +operating conditions of the system or the action of external factors.Is it possible to give examples?
For example a server farm decide to save power by reduce cooling cost, by lowering TDP. This can be done remotely. This will result in notification of a lower performance value or even perf=eff=0 on some CPUs via HFI. Intel CPU has capability to change TDP level runtime. Or if the system is over heating the firmware can indicate lower performance, so OSPM can take action.
quoted
The rate +at which these capabilities are updated is specific to each processor model. On +some models, capabilities are set at boot time and never change. On others, +capabilities may change every tens of milliseconds. + +The kernel or a userspace policy daemon can use these capabilities to modify +task placement decisions. For instance, if either the performance or energy +capabilities of a given logical processor becomes zero, it is an indication that +the hardware recommends to the operating system to not schedule any tasks on +that processor for performance or energy efficiency reasons, respectively.How the userspace can be involved in these decisions? If the performance is impacted then that should be reflected in the CPU capacity. The scheduler will prevent to put task on CPU with a low capacity, no? I'm also worried about the overhead of the userspace notifications. That sounds like similar to the thermal pressure? Wouldn't make sense to create a generic component where HFI, cpufreq cooling, LMh, etc ... are the backend?
The problem is treatment of perf/eff == 0 of a CPU, which we can indicate as capacity = 0 to scheduler. But this doesn't prevent scheduler for using that CPU on a overloaded system. We can offline that CPU in kernel, which will be intrusive without notifying user space or may fail for CPU0. Tried cpu idle injection, remove from cpu sets. But doesn't work when interrupt are affined to that CPU, soft irqs or timer scheduled there. Here the notification are in order of several ms in order ( In reality they are in seconds for current use cases). These are not emergency events. Same as other thermal notifications, if something urgent FW can already force to lowest performance without even notifying user space. Thanks, Srinivas
quoted
+Implementation details for Linux +-------------------------------- + +The infrastructure to handle thermal event interrupts has two parts. In the +Local Vector Table of a CPU's local APIC, there exists a register for the +Thermal Monitor Register. This register controls how interrupts are delivered +to a CPU when the thermal monitor generates and interrupt. Further details +can be found in the Intel SDM Vol. 3 Section 10.5 [1]_. + +The thermal monitor may generate interrupts per CPU or per package. The HFI +generates package-level interrupts. This monitor is configured and initialized +via a set of machine-specific registers. Specifically, the HFI interrupt and +status are controlled via designated bits in the IA32_PACKAGE_THERM_INTERRUPT +and IA32_PACKAGE_THERM_STATUS registers, respectively. There exists one HFI +table per package. Further details can be found in the Intel SDM Vol. 3 +Section 14.9 [1]_. + +The hardware issues an HFI interrupt after updating the HFI table and is ready +for the operating system to consume it. CPUs receive such interrupt via the +thermal entry in the Local APIC's Local Vector Table. + +When servicing such interrupt, the HFI driver parses the updated table and +relays the update to userspace using the thermal notification framework. Given +that there may be many HFI updates every second, the updates relayed to +userspace are throttled at a rate of CONFIG_HZ jiffies. + +References +---------- + +.. [1] https://www.intel.com/sdm