Thread (22 messages) 22 messages, 6 authors, 2021-04-27

Re: [RFC PATCH 5/7] iio:ABI docs: Combine sysfs-bus-iio-humidity-hdc2010/hdc100x into one file

From: Jonathan Cameron <jic23@kernel.org>
Date: 2021-02-21 16:09:26
Also in: linux-iio

On Sun, 17 Jan 2021 15:12:40 -0800
Matt Ranostay [off-list ref] wrote:
On Sun, Jan 17, 2021 at 7:40 AM Jonathan Cameron [off-list ref] wrote:
quoted
From: Jonathan Cameron <Jonathan.Cameron@huawei.com>

These contain only one entry for out_current_heater_raw (_available).
Document this in a new sysfs-bus-iio-humidity file, and make it a little
more generic by allowing for non 0/1 values.

Fixes:
$ scripts/get_abi.pl validate
Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:0  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:0
Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:1  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:1

Cc: Eugene Zaikonnikov <redacted>
Cc: Matt Ranostay <matt.ranostay@konsulko.com>
Reported-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>  
Reviewed-by: Matt Ranostay <matt.ranostay@konsulko.com>
Applied, thanks

J
quoted
---
 ...s-bus-iio-humidity-hdc2010 => sysfs-bus-iio-humidity} | 3 ++-
 Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 ---------
 2 files changed, 2 insertions(+), 10 deletions(-)
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 b/Documentation/ABI/testing/sysfs-bus-iio-humidity
similarity index 79%
rename from Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010
rename to Documentation/ABI/testing/sysfs-bus-iio-humidity
index 5b78af5f341d..cb0d7e75d297 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010
+++ b/Documentation/ABI/testing/sysfs-bus-iio-humidity
@@ -6,4 +6,5 @@ Description:
                Controls the heater device within the humidity sensor to get
                rid of excess condensation.

-               Valid control values are 0 = OFF, and 1 = ON.
+               In some devices, this is just a switch in which case 0 = OFF,
+               and 1 = ON.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x b/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
deleted file mode 100644
index b72bb62552cf..000000000000
--- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
+++ /dev/null
@@ -1,9 +0,0 @@
-What:          /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw
-What:          /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available
-KernelVersion: 4.3
-Contact:       linux-iio@vger.kernel.org
-Description:
-               Controls the heater device within the humidity sensor to get
-               rid of excess condensation.
-
-               Valid control values are 0 = OFF, and 1 = ON.
--
2.30.0
 
  
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help