On Mon, 06 Apr 2026 19:05:55 +0530, Kamal Wadhwa wrote:
The temp-alarm driver probe is failing for the pmh0104 PMICs on glymur.
[ 3.999713] spmi-temp-alarm c426000.spmi:pmic@8:temp-alarm@a00: error -ENODEV: failed to register sensor
[ 4.015066] spmi-temp-alarm c426000.spmi:pmic@9:temp-alarm@a00: error -ENODEV: failed to register sensor
[ 4.033908] spmi-temp-alarm c437000.spmi:pmic@b:temp-alarm@a00: error -ENODEV: failed to register sensor
This happens because thermal zone associated with the temp alarm was
defined under the thermal zones parent node which had a typo (used `_` in
place of `-`). Correct the typo to fix probe failure.
[...]
Applied, thanks!
[1/1] arm64: dts: qcom: fix temp-alarm probe failure for PMH0104 on Glymur
commit: e8fae9152e100b4bb30d38b25bc9c81623e8e91e
Best regards,
--
Bjorn Andersson [off-list ref]