Hi Damon,
Am Donnerstag, 7. Mai 2026, 13:29:39 Mitteleuropäische Sommerzeit schrieb Damon Ding:
quoted hunk ↗ jump to hunk
The RK3588 eDP controller needs the video datapath clock "hclk" to work
well. Previously, it works without explicitly adding this clock because
the 'rockchip,vo-grf = <&vo1_grf>' property implicitly enables HCLK_VO1.
Fixes: f855146263b1 ("dt-bindings: display: rockchip: analogix-dp: Add support for RK3588")
Signed-off-by: Damon Ding <redacted>
---
.../bindings/display/rockchip/rockchip,analogix-dp.yaml | 4 +++-
1 file changed, 3 insertions(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml b/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml
index d99b23b88cc5..d2bc8636b626 100644
--- a/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml
+++ b/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml
@@ -26,7 +26,9 @@ properties:
items:
- const: dp
- const: pclk
- - const: grf
+ - enum:
+ - grf
+ - hclk
are you sure about that?
The edp uses the vo1-grf - so what enables its clock?
For example the hdmi controllers on rk3588 also use the vo1-grf and
explicitly handle that clock.
So who does it for the eDP?
Heiko
power-domains:
maxItems: 1