On 8/12/25 9:49 PM, Jonathan Santos wrote:
quoted hunk ↗ jump to hunk
Use devm_regulator_get_enable_read_voltage function as a standard and
concise way of reading the voltage from the regulator and keep the
regulator enabled. Replace the regulator descriptor with the direct
voltage value in the device struct.
Signed-off-by: Jonathan Santos <redacted>
---
drivers/iio/adc/ad7768-1.c | 29 +++++++----------------------
1 file changed, 7 insertions(+), 22 deletions(-)
diff --git a/drivers/iio/adc/ad7768-1.c b/drivers/iio/adc/ad7768-1.c
index 36ba208fc119..d0b9764a8f92 100644
--- a/drivers/iio/adc/ad7768-1.c
+++ b/drivers/iio/adc/ad7768-1.c
@@ -225,7 +225,7 @@ struct ad7768_state {
struct spi_device *spi;
struct regmap *regmap;
struct regmap *regmap24;
- struct regulator *vref;
+ int vref_uv;
struct regulator_dev *vcm_rdev;
unsigned int vcm_output_sel;
struct clk *mclk;@@ -809,7 +809,7 @@ static int ad7768_read_raw(struct iio_dev *indio_dev,
return IIO_VAL_INT;
case IIO_CHAN_INFO_SCALE:
- scale_uv = regulator_get_voltage(st->vref);
+ scale_uv = st->vref_uv;
if (scale_uv < 0)
return scale_uv;
Can also drop the error check since we've already done that in probe.