On Wed, Aug 28, 2024 at 10:51:25PM +0200, Vasileios Amoiridis wrote:
quoted hunk ↗ jump to hunk
Add interrupt options for BMP3xx and BMP5xx devices as well.
Signed-off-by: Vasileios Amoiridis <redacted>
---
.../bindings/iio/pressure/bmp085.yaml | 22 ++++++++++++++++++-
1 file changed, 21 insertions(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/iio/pressure/bmp085.yaml b/Documentation/devicetree/bindings/iio/pressure/bmp085.yaml
index 6fda887ee9d4..edf5901c6c87 100644
--- a/Documentation/devicetree/bindings/iio/pressure/bmp085.yaml
+++ b/Documentation/devicetree/bindings/iio/pressure/bmp085.yaml
@@ -48,14 +48,34 @@ properties:
interrupts:
description:
- interrupt mapping for IRQ (BMP085 only)
+ interrupt mapping for IRQ. Supported in BMP085, BMP3xx, BMP5xx
maxItems: 1
+ drive-open-drain:
+ description:
+ set if the interrupt pin should be configured as open drain.
+ If not set, defaults to push-pull configuration.
I don't think you implemented my comment.
+
required:
- compatible
- vddd-supply
- vdda-supply
+allOf:
+ - if:
not:
+ properties:
+ compatible:
+ enum:
+ - bosch,bmp085
+ - bosch,bmp380
+ - bosch,bmp580
+ then:
+ properties:
+ interrupts: true
+ else:
so no need for else:.
Best regards,
Krzysztof