On 27/08/2024 11:29, Jan Kiszka wrote:
quoted
quoted
+ reg:
+ minItems: 2
maxItems instead.
Can change, but maybe use the chance to explain to me why "maxItems" and
why also "instead".
because minItems is not constrained. maxItem is and, in case of lack of
minItems, it implies minItems.
quoted
quoted
+
+ reg-names:
+ items:
+ - const: cfg
+ - const: tlbif
+
+ interrupts:
+ items:
+ - description: fault interrupt
+
+ interrupt-names:
+ items:
+ - const: pvu
+
+required:
+ - compatible
+ - reg
+ - interrupts
+ - interrupt-names
+
+additionalProperties: false
+
+examples:
+ - |
+ ti-pvu@30f80000 {
Node names should be generic. See also an explanation and list of
examples (not exhaustive) in DT specification:
https://devicetree-specification.readthedocs.io/en/latest/chapter2-devicetree-basics.html#generic-names-recommendation
for sure "ti" is not generic. pvu is the device name.
No problem - which one do you propose for this type of device?
iommu, but if this is not suitable, at pvu could stay. Just the first
'ti-' does not sound right in that case.
Best regards,
Krzysztof