Thread (11 messages) 11 messages, 3 authors, 2021-08-30

Re: [PATCH 1/3] arm: dts: qcom: apq8064: Use 27MHz PXO clock as DSI PLL reference

From: Marijn Suijten <marijn.suijten@somainline.org>
Date: 2021-08-30 08:28:22
Also in: linux-arm-msm, lkml, phone-devel

Hi Dmitry,

On 8/30/21 3:18 AM, Dmitry Baryshkov wrote:
On Sun, 29 Aug 2021 at 23:30, Marijn Suijten
[off-list ref] wrote:
quoted
The 28NM DSI PLL driver for msm8960 calculates with a 27MHz reference
clock and should hence use PXO, not CXO which runs at 19.2MHz.

Note that none of the DSI PHY/PLL drivers currently use this "ref"
clock; they all rely on (sometimes inexistant) global clock names and
usually function normally without a parent clock.  This discrepancy will
be corrected in a future patch, for which this change needs to be in
place first.

Cc: Dmitry Baryshkov <redacted>
Signed-off-by: Marijn Suijten <marijn.suijten@somainline.org>
Reviewed-by: Dmitry Baryshkov <redacted>

Checked the downstream driver, it always uses 27 MHz clock in calculations.

Given our concerns for msm8974 not updating DT in parallel with the 
kernel (hence the need for a global-name fallback because "ref" is 
missing from the DT), should we worry about the same for apq8064?  That 
is, is there a chance that the kernel but not the firmware is upgraded 
leading to the wrong parent clock being used?  The msm8960 variant of 
the 28nm PLL driver uses parent_rate in a few places and might read 
cxo's 19.2MHz erroneously instead of using pxo's 27MHz.

- Marijn