On Thu, 19 Aug 2021 20:48:44 +0800, yangcong wrote:
The auo,b101uan08.3 panel (already supported by this driver) has
a 3.3V rail that needs to be turned on. For previous users of
this panel this voltage was directly output by pmic. On a new
user (the not-yet-upstream sc7180-trogdor-mrbland board) we need
to turn the 3.3V rail on.
Signed-off-by: yangcong <redacted>
---
.../devicetree/bindings/display/panel/boe,tv101wum-nl6.yaml | 4 ++++
1 file changed, 4 insertions(+)
My bot found errors running 'make DT_CHECKER_FLAGS=-m dt_binding_check'
on your patch (DT_CHECKER_FLAGS is new in v5.13):
yamllint warnings/errors:
dtschema/dtc warnings/errors:
/builds/robherring/linux-dt-review/Documentation/devicetree/bindings/display/panel/boe,tv101wum-nl6.example.dt.yaml: panel@0: 'pp3300-supply' is a required property
From schema: /builds/robherring/linux-dt-review/Documentation/devicetree/bindings/display/panel/boe,tv101wum-nl6.yaml
doc reference errors (make refcheckdocs):
See https://patchwork.ozlabs.org/patch/1518662
This check can fail if there are any dependencies. The base for a patch
series is generally the most recent rc1.
If you already ran 'make dt_binding_check' and didn't see the above
error(s), then make sure 'yamllint' is installed and dt-schema is up to
date:
pip3 install dtschema --upgrade
Please check and re-submit.