On Mon, Aug 16, 2021 at 3:32 AM Krzysztof Kozlowski
[off-list ref] wrote:
On 16/08/2021 09:53, Lukasz Luba wrote:
quoted
Hi Krzysztof,
On 8/13/21 1:54 PM, Krzysztof Kozlowski wrote:
quoted
Convert Samsung Exynos5422 SoC frequency and voltage scaling for
Dynamic Memory Controller to DT schema format using json-schema.
Signed-off-by: Krzysztof Kozlowski <redacted>
---
.../memory-controllers/exynos5422-dmc.txt | 84 -----------
.../samsung,exynos5422-dmc.yaml | 137 ++++++++++++++++++
MAINTAINERS | 2 +-
I'm not an expert in this DT scripts and why it complains. Maybe it
complains because the "samsung,exynos-ppmu" is defined in the .txt
file... (?)
Although, in general looks OK.
Acked-by: Lukasz Luba <lukasz.luba@arm.com>
I think the warning (triggered by DT_CHECKER_FLAGS=-m) can be ignored
because it complains about compatible in example which is not present in
the bindings. Usually it means someone wrote example not matching the
bindings (e.g. a typo in compatible) but here it is on purpose.
Ultimately, it will mean the binding is undocumented (or a typo). But
right now, it means the binding is undocumented with a schema. It's
off by default because there's still about 80 warnings. It's turned on
for the bot so we don't add more. So please don't ignore it.
Rob