Re: [PATCH 3/3] dt-bindings: power: supply: max17042: describe interrupt

From: Rob Herring <robh@kernel.org>
Date: 2021-08-17 22:28:18
Also in: linux-pm, lkml

On Mon, 16 Aug 2021 10:27:16 +0200, Krzysztof Kozlowski wrote:
The Maxim 17042-family of fuel gauges are often embedded in other Maxim
chips, e.g. in Maxim 77693 which is a companion power management IC.
In such designs there might be actually two interrupts:
 - INTB signaling change from charger, flash or MUIC,
 - ALERT signaling change from fuel gauge.

Describe the interrupt in bindings to make it clear it is about the fuel
gauge ALERT interrupt, not the INT.

Signed-off-by: Krzysztof Kozlowski <redacted>
---
 .../devicetree/bindings/power/supply/maxim,max17042.yaml        | 2 ++
 1 file changed, 2 insertions(+)
Acked-by: Rob Herring <robh@kernel.org>