Thread (6 messages) flat view 6 messages, 3 authors, 2021-03-26

Re: [PATCH net-next v4 2/2] net: axienet: Enable more clocks

From: Andrew Lunn <andrew@lunn.ch>
Date: 2021-03-26 12:15:29
Also in: netdev

On Thu, Mar 25, 2021 at 06:04:38PM -0600, Robert Hancock wrote:
This driver was only enabling the first clock on the device, regardless
of its name. However, this controller logic can have multiple clocks
which should all be enabled. Add support for enabling additional clocks.
The clock names used are matching those used in the Xilinx version of this
driver as well as the Xilinx device tree generator, except for mgt_clk
which is not present there.

For backward compatibility, if no named clocks are present, the first
clock present is used for determining the MDIO bus clock divider.

Reviewed-by: Radhey Shyam Pandey <redacted>
Signed-off-by: Robert Hancock <redacted>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>

    Andrew