On 3/15/21 9:21 PM, Chris Packham wrote:
On 16/03/21 4:43 pm, Guenter Roeck wrote:
quoted
On 3/15/21 7:35 PM, Chris Packham wrote:
quoted
The BPA-RS600 is a compact 600W AC to DC removable power supply module.
Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
---
<snip>
quoted
quoted
+
+static int bpa_rs600_read_word_data(struct i2c_client *client, int page,
+ int phase, int reg)+{
+ int ret;
+
+ if (page > 0)
+ return -ENXIO;
+
+ switch (reg) {
+ case PMBUS_VIN_UV_FAULT_LIMIT:
+ case PMBUS_VIN_OV_FAULT_LIMIT:
+ case PMBUS_VOUT_UV_FAULT_LIMIT:
+ case PMBUS_VOUT_OV_FAULT_LIMIT:
+ ret = -ENXIO;
Is that needed ? Why not -ENODATA ?
Basically these commands get responses on the bus but they don't have
valid data (nor are they documented in the datasheet). I'll add a
comment to that effect.
If I'm reading things correctly -ENODATA is a signal to
_pmbus_read_word_data use the "normal" read operation. So I need to
Correct.
return something other than that. I found another driver (mp2975.c)
doing the same thing for what I assume are similar reasons so I went
with -ENXIO.
-ENXIO is ok, but please document it.
Thanks,
Guenter