Re: [PATCH 08/46] dt-bindings:iio:health:ti,afe4404: txt to yaml conversion
From: Jonathan Cameron <jic23@kernel.org>
Date: 2020-12-30 12:22:02
Also in:
linux-iio
On Fri, 18 Dec 2020 13:42:19 -0600 Rob Herring [off-list ref] wrote:
On Sat, Oct 31, 2020 at 1:51 PM Jonathan Cameron [off-list ref] wrote:quoted
From: Jonathan Cameron <Jonathan.Cameron@huawei.com> This basically has same questions as for the afe4403. We could combine the two bindings, but as the drivers are separate and it would be a little fiddly due to different buses let's keep the separating. To repeat questions from the ti,afe4403 binding. A few questions came up whilst converting this one. 1) What is actually required? - Checking Linux driver, interrupt is not, and the tx-supply could be supplied by a stub regulator as long as it's always on. As such I have reduced the required list to just compatible and reg. 2) What is the regulator called? - It's tx-supply in the binding doc, but the driver request tx_sup I've left this alone for now. Andrew could you confirm what is intended for this? Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Cc: Andrew F. Davis <redacted> --- .../bindings/iio/health/afe4404.txt | 29 ----------- .../bindings/iio/health/ti,afe4404.yaml | 51 +++++++++++++++++++ 2 files changed, 51 insertions(+), 29 deletions(-)diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt deleted file mode 100644 index 0b52830a0d9c..000000000000 --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt +++ /dev/null@@ -1,29 +0,0 @@ -Texas Instruments AFE4404 Heart rate and Pulse Oximeter - -Required properties: - - compatible : Should be "ti,afe4404". - - reg : I2C address of the device. - - tx-supply : Regulator supply to transmitting LEDs. - - interrupts : The interrupt line the device ADC_RDY pin is - connected to. For details refer to, - ../interrupt-controller/interrupts.txt. - -Optional properties: - - reset-gpios : GPIO used to reset the device. - For details refer to, ../gpio/gpio.txt. - -Example: - -&i2c2 { - heart_mon@58 { - compatible = "ti,afe4404"; - reg = <0x58>; - - tx-supply = <&vbat>; - - interrupt-parent = <&gpio1>; - interrupts = <28 IRQ_TYPE_EDGE_RISING>; - - reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>; - }; -};diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml new file mode 100644 index 000000000000..187b99b22312 --- /dev/null +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml@@ -0,0 +1,51 @@ +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter + +maintainers: + - Andrew F. Davis <afd@ti.com> + +properties: + compatible: + const: ti,afe4403Typo here, which causes this warning: Documentation/devicetree/bindings/iio/health/ti,afe4403.example.dt.yaml: heart_mon@0: 'spi-max-frequency' does not match any of the regexes: 'pinctrl-[0-9]+' Took me a minute staring at ti,afe4403.yaml to figure out what was happening.
Doh! Patch on it's way. Thanks, Jonathan
Rob