Thread (1 message) 1 message, 1 author, 2020-11-23

[PATCH v2 4/4] dt-bindings: pwm: pca9685: Add staggered-outputs property

flat view
DORMANTno replies

From: Clemens Gruber <hidden>
Date: 2020-11-23 16:40:18
Also in: linux-pwm, lkml
Subsystem: open firmware and flattened device tree bindings, pwm subsystem, the rest · Maintainers: Rob Herring, Krzysztof Kozlowski, Conor Dooley, Uwe Kleine-König, Linus Torvalds

The pca9685 driver supports a new staggered-outputs property for reduced
current surges and EMI. This adds documentation for the new DT property.

Signed-off-by: Clemens Gruber <redacted>
---
 Documentation/devicetree/bindings/pwm/nxp,pca9685-pwm.txt | 2 ++
 1 file changed, 2 insertions(+)
diff --git a/Documentation/devicetree/bindings/pwm/nxp,pca9685-pwm.txt b/Documentation/devicetree/bindings/pwm/nxp,pca9685-pwm.txt
index f21b55c95738..911bbb65984e 100644
--- a/Documentation/devicetree/bindings/pwm/nxp,pca9685-pwm.txt
+++ b/Documentation/devicetree/bindings/pwm/nxp,pca9685-pwm.txt
@@ -12,6 +12,8 @@ Optional properties:
   - invert (bool): boolean to enable inverted logic
   - open-drain (bool): boolean to configure outputs with open-drain structure;
 		       if omitted use totem-pole structure
+  - staggered-outputs (bool): boolean to enable staggered output ON times to
+			      minimize current surges and EMI
 
 Example:
 
-- 
2.29.2