The correct compatible string is "gpio-mux" (see
bindings/mux/gpio-mux.txt).
Signed-off-by: Christian Eggers <ceggers@arri.de>
Cc: <redacted>
---
.../devicetree/bindings/iio/multiplexer/io-channel-mux.txt | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/iio/multiplexer/io-channel-mux.txt b/Documentation/devicetree/bindings/iio/multiplexer/io-channel-mux.txt
index c82794002595..89647d714387 100644
--- a/Documentation/devicetree/bindings/iio/multiplexer/io-channel-mux.txt
+++ b/Documentation/devicetree/bindings/iio/multiplexer/io-channel-mux.txt
@@ -21,7 +21,7 @@ controller state. The mux controller state is described in
Example:
mux: mux-controller {
- compatible = "mux-gpio";
+ compatible = "gpio-mux";
#mux-control-cells = <0>;
mux-gpios = <&pioA 0 GPIO_ACTIVE_HIGH>,--