Thread (42 messages) flat view 42 messages, 6 authors, 2020-06-26

Re: [RFC PATCH 3/9] net: dsa: hellcreek: Add PTP clock support

From: Kurt Kanzenbach <kurt@linutronix.de>
Date: 2020-06-19 08:26:49
Also in: netdev

Hi Andrew,

On Thu Jun 18 2020, Andrew Lunn wrote:
quoted
+static u64 __hellcreek_ptp_clock_read(struct hellcreek *hellcreek)
+{
+	u16 nsl, nsh, secl, secm, sech;
+
+	/* Take a snapshot */
+	hellcreek_ptp_write(hellcreek, PR_COMMAND_C_SS, PR_COMMAND_C);
+
+	/* The time of the day is saved as 96 bits. However, due to hardware
+	 * limitations the seconds are not or only partly kept in the PTP
+	 * core. That's why only the nanoseconds are used and the seconds are
+	 * tracked in software. Anyway due to internal locking all five
+	 * registers should be read.
+	 */
+	sech = hellcreek_ptp_read(hellcreek, PR_SS_SYNC_DATA_C);
+	secm = hellcreek_ptp_read(hellcreek, PR_SS_SYNC_DATA_C);
+	secl = hellcreek_ptp_read(hellcreek, PR_SS_SYNC_DATA_C);
+	nsh  = hellcreek_ptp_read(hellcreek, PR_SS_SYNC_DATA_C);
+	nsl  = hellcreek_ptp_read(hellcreek, PR_SS_SYNC_DATA_C);
+
+	return (u64)nsl | ((u64)nsh << 16);
Hi Kurt

What are the hardware limitations? There seems to be 48 bits for
seconds? That allows for 8925104 years?
In theory, yes. Due to hardware hardware considerations only a few or
none of these bits are used for the seconds. The rest is zero. Meaning
that the wraparound is not 8925104 years, but at e.g. 8 seconds when
using 3 bits for the seconds.

I've discussed this the Hirschmann people and they suggested to use the
nanoseconds only. That's what I did here.
quoted
+static u64 __hellcreek_ptp_gettime(struct hellcreek *hellcreek)
+{
+	u64 ns;
+
+	ns = __hellcreek_ptp_clock_read(hellcreek);
+	if (ns < hellcreek->last_ts)
+		hellcreek->seconds++;
+	hellcreek->last_ts = ns;
+	ns += hellcreek->seconds * NSEC_PER_SEC;
So the assumption is, this gets called at least once per second. And
if that does not happen, there is no recovery. The second is lost.
Yes, exactly. If a single overflow is missed, then the time is wrong.
I'm just wondering if there is something more robust using what the
hardware does provide, even if the hardware is not perfect.
I don't think there's a more robust way to do this. The overflow period
is a second which should be enough time to catch the overflow even if
the system is loaded. We did long running tests for days and the
mechanism worked fine. We could also consider to move the delayed work
to a dedicated thread which could be run with real time (SCHED_FIFO)
priority. But, I didn't see the need for it.

Thanks,
Kurt

Attachments

Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help