Thread (37 messages) 37 messages, 3 authors, 2020-04-09

Re: [PATCH v2 13/17] dt-bindings: marvell,mmp2: Add clock ids for the thermal sensors

From: Stephen Boyd <sboyd@kernel.org>
Date: 2020-03-21 01:25:23
Also in: linux-arm-kernel, linux-clk, lkml

Quoting Lubomir Rintel (2020-03-09 12:42:50)
There seems to be a single thermal sensor block on MMP2 and a couple
more on MMP3. Add definitions for their respective clocks.

Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>

---
Applied to clk-next
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help