Thread (25 messages) 25 messages, 7 authors, 2019-09-06

Re: [PATCHv3 01/10] dt-bindings: omap: add new binding for PRM instances

From: Rob Herring <robh@kernel.org>
Date: 2019-09-02 13:39:16
Also in: linux-arm-kernel, linux-omap

On Fri, Aug 30, 2019 at 03:18:07PM +0300, Tero Kristo wrote:
Add new binding for OMAP PRM (Power and Reset Manager) instances. Each
of these will act as a power domain controller and potentially as a reset
provider.
Converting this to schema would be nice.
Signed-off-by: Tero Kristo <redacted>
---
 .../devicetree/bindings/arm/omap/prm-inst.txt | 31 +++++++++++++++++++
bindings/reset/
quoted hunk ↗ jump to hunk
 1 file changed, 31 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/arm/omap/prm-inst.txt
diff --git a/Documentation/devicetree/bindings/arm/omap/prm-inst.txt b/Documentation/devicetree/bindings/arm/omap/prm-inst.txt
new file mode 100644
index 000000000000..7c7527c37734
--- /dev/null
+++ b/Documentation/devicetree/bindings/arm/omap/prm-inst.txt
@@ -0,0 +1,31 @@
+OMAP PRM instance bindings
+
+Power and Reset Manager is an IP block on OMAP family of devices which
+handle the power domains and their current state, and provide reset
+handling for the domains and/or separate IP blocks under the power domain
+hierarchy.
+
+Required properties:
+- compatible:	Must be one of:
+		"ti,am3-prm-inst"
+		"ti,am4-prm-inst"
+		"ti,omap4-prm-inst"
+		"ti,omap5-prm-inst"
+		"ti,dra7-prm-inst"
'-inst' seems a bit redundant.
+- reg:		Contains PRM instance register address range
+		(base address and length)
+
+Optional properties:
+- #reset-cells:	Should be 1 if the PRM instance in question supports resets.
+- clocks:	Associated clocks for the reset signals if any. Certain reset
+		signals can't be toggled properly without functional clock
+		being active for them.
+
+Example:
+
+prm_dsp2: prm@1b00 {
reset-controller@...
+	compatible = "ti,dra7-prm-inst";
+	reg = <0x1b00 0x40>;
+	#reset-cells = <1>;
+	clocks = <&dsp2_clkctrl DRA7_DSP2_MMU0_DSP2_CLKCTRL 0>;
+};
-- 
2.17.1

--
Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki. Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help