Hi Johan,
Am Samstag, 29. Dezember 2018, 14:33:14 CET schrieb Johan Jonker:
From: Mark Yao <redacted>
This patch adds the rk3066 VOP definitions.
The VOP or LCD Controller serves as interface between
framebuffer memory and a display device (LCD panel or TV set).
This SOC has two symmetrical LCDC's for a dual panel application.
A LCDC has 5 display layers.
Only 3 are used here.
- Video layer 0 (Win0)
- Video layer 1 (Win1)
- OSD layer (Win2)
Patch itself looks good, we'll need to wait a bit to give Rob a chance
to look at the (simple) dt-binding change and I'll drop the paragraph
about the display layers when applying.
Looking at the rk3066-manual, the lcdcs really only have 3 fully usable
layers + the special cursor layer which is right now not really usable in
a drm context, so the above paragraph is misleading, so I'll just drop it.
Heiko
Win0 and Win1 are exchangeable.
Maximum resolution is 1920x1080.
The LCDC0 output is connected to:
- LCDC0 IO (without IOMUX)
- HDMI TX video input
The LCDC1 output is connected to:
- LCDC1 IO (with IOMUX)
- HDMI TX video input
The HDMI TX input can switch between LCDC0 and LCDC1.
Signed-off-by: Mark Yao <redacted>