Thread (16 messages) 16 messages, 7 authors, 2018-06-11

Re: [RFC v2 2/2] dt-bindings: mipi-dsi: Add dual-channel DSI related info

From: Brian Norris <briannorris@chromium.org>
Date: 2018-06-07 21:10:20
Also in: dri-devel, linux-arm-msm

Hi,

I only have a little bit to add, but Heiko did solicit my opinion.

On Thu, Jun 07, 2018 at 03:25:18PM +0200, Heiko Stuebner wrote:
Am Donnerstag, 7. Juni 2018, 12:39:03 CEST schrieb Andrzej Hajda:
quoted
On 07.06.2018 01:08, Heiko Stuebner wrote:
quoted
Am Mittwoch, 6. Juni 2018, 18:07:46 CEST schrieb Archit Taneja:
quoted
On Wednesday 06 June 2018 04:16 PM, Heiko Stübner wrote:
quoted
Am Mittwoch, 6. Juni 2018, 12:21:16 CEST schrieb Archit Taneja:
quoted
On Wednesday 06 June 2018 02:00 PM, Heiko Stübner wrote:
quoted
Am Mittwoch, 6. Juni 2018, 07:59:29 CEST schrieb Archit Taneja:
quoted
On Monday 04 June 2018 05:47 PM, Heiko Stuebner wrote:
quoted
Am Donnerstag, 18. Januar 2018, 05:53:55 CEST schrieb Archit Taneja:
quoted
Add binding info for peripherals that support dual-channel DSI. Add
corresponding optional bindings for DSI host controllers that may
be configured in this mode. Add an example of an I2C controlled
device operating in dual-channel DSI mode.

Signed-off-by: Archit Taneja <redacted>
Looks like a great solution for that problem, so
Reviewed-by: Heiko Stuebner <heiko@sntech.de>

As I'm looking into that for my rk3399-scarlet device right now and
couldn't find this patchset in the kernel yet, is it planned to
merge or refresh these binding changes or were problems encountered.

At least an Ack/Review from Rob seems to be missing.
I forgot about these patches. Rob had reviewed the first one in
the set the second one still needed an Ack. I'll post a v3
that adds the Reviewed-bys and fixes a small typo.
very nice ... because it looks like yesterday I managed to make the
Rockchip dsi work in dual mode following this.

But one question came up, do you really want two input ports on the
panel
side? I.e. hardware-wise, I guess the panel will have one 8-lane or so
input thatonly gets split up on the soc side onto 2 dsi controllers?
I think all dual DSI panels actually have 2 DSI controllers/parsers
within them, one on each port. The MIPI DSI spec doesn't support 8
lanes. Also, the pixels coming out of the host are distributed among
the lanes differently than what would have been the case with a
'theoretical' 8 lane receiver.

Other than that, some dual DSI panels only accept DSI commands on the
'master' port, where as others expect the same command to be sent
across
both the ports.

Therefore, I think it's better to represent dual DSI panels having 2
DSI input ports.

Your DT looks good to me.
Hmm, that doesn't match up then ;-) ... as my dt uses 2 endpoints
in one port for the dsi-links.
Sorry, I didn't notice you'd created two endpoints within a single port.

I don't think I'm particular about 2 ports vs 1 port with 2 endpoints.
They both seem okay to me as long as we follow it consistently. I'm
myself not 100% sure of how to figure where one should prefer endpoints
over ports. Maybe someone more familiar with the of graph bindings
could comment here.
Port should describe physical port, endpoint are used to describe
multiple links to the same port. If the panel has two physical DSI
interfaces it should use two ports.
That again leaves a bit of space for interpretation ;-) .
Does it really? DSI maxes out at 4 lanes, so more than 4 lanes is
clearly not a single standard port. Additionally, the code we're
currently using in Chrome OS actually sends the same commands to each
DSI separately (I'm not sure if it's actually required by the panels
were using), so again, they are to some extent logically independent.
A dual-dsi display is probably pretty useless with only one controller
connected to it, as its 4 lanes cannot satisfy the required 8 lanes
of the panel.
Probably, although technically you can usually display on half the
screen, if you have only have 1 working DSI.
See [0] for current WIP panel addition.
[Was already on the lists but needs cleanup]



[0] https://github.com/mmind/linux-rockchip/commit/459bc1a1599377c2c5408724e82619a4602a953d#diff-5d6d6ddab4fd282102d23d2c02e835f8R381

quoted
quoted
quoted
quoted
The issue I see with using ports and not endpoints for dual-dsi links
is with distinguishing between input and output ports.

For a panel that's easy, as you every port will be an input port and if
you have 2, it's supposed dual-dsi. But for example I guess there might
exist some dual-dsi-to-something bridges, where you would end up
with say 3 (or even more) ports ... two dual-dsi inputs and 1 or more
outputs.
Okay, I get your point here. Although, even if the remote device had
exactly 2 ports. Is it safe to assume that port #0 is an input port and
port #1 is an output port? Is that the norm?
I don't think that anything like that is specified anywhere, so you cannot
assume anything about what a port contains.
Ports are defined per device-node and port number assignment should be
described in particular device bindings. So device driver knows well
which functions should be assigned to which port. But it is private
matter of the device/device driver. Different device bindings can assign
different number for input and output ports, but since ports are private
thing for devices it should not be a problem.
Agreed. And if Heiko needs a specific example close to home: all the
Rockchip display bindings do this similarly; for example
display/rockchip/analogix_dp-rockchip.txt describes exactly which port
numbers and enpoints mean what:

- ports: there are 2 port nodes with endpoint definitions as defined in
  Documentation/devicetree/bindings/media/video-interfaces.txt.
    Port 0: contained 2 endpoints, connecting to the output of vop.
    Port 1: contained 1 endpoint, connecting to the input of panel.
quoted
I do not see why do you have such issue, could you describe it more.
quoted
quoted
I've at least seen one device (toshiba,tc358767 bridge) that can
actually take either DPI as input or DSI based on how you configure it.
There are 2 input ports here, port #0 for DSI and port #1 for DPI. Would
it have made sense here to have a single port and 2 endpoints here too?
Nope, I guess having a port for DPI input, one port for DSI input makes
quite a lot of sense. And then you can have the input-specifics living in
the endpoints like dual links or so.
quoted
quoted
While the following argument might not be 100% valid from a dt-purity
standpoint implementing this might get hairy for _any_ operating system,
as you will need each panel/bridge to tell what the ports are used for.
Yeah.
Each panel/bridge should know what his ports are used for, but to who
and why you want to communicate it?
I'll do that below :-)

quoted
quoted
quoted
quoted
I.e. in my endpoint based mapping, right now I have this nice and
generic
WIP function to parse the of_graph and get the master+slave nodes:

https://github.com/mmind/linux-rockchip/blob/tmp/rk3399-gru-bob-scarlet/
drivers/gpu/drm/rockchip/dw-mipi-dsi-rockchip.c#L697 [0]
I'd tried out something locally before posting this patch, I don't have
the code for it, but I can describe the steps I took. This code expects
the panel/bridge to have 2 input ports.
Which again would be very much panel-specific as you cannot assume
to much about the ports.
quoted
1. DSI0 host driver looks up its output port, gets the remote endpoint,
and get this endpoint's parent (using
of_graph_get_remote_port_parent()). Keeps the parent device node in a
temp variable.

2. DSI1 host driver does the same thing.

3. DSI0 and DSI1 check whether their outputs are connected to the
same device. If so, they're in dual DSI mode. If not, they are
operating independently.

The positive of this approach is that we don't need to make any
assumptions about the panel/bridge's port numbers, which is great.
The negative is that our DSI controller instances now need to query
each other, which can be messy, but not too hard to implement.
I think detection of dual dsi and whole configuration thing of dual-dsi
should be done using in-kernel frameworks (maybe new ones :) ).
Could you describe necessary configuration steps to be performed, what
info should be passed from who to who, etc. It would be easier to discuss.
The base setup is the rk3399 soc, which has 2 completely separate
dw-mipi-dsi controllers.

Gru-Scarlet (a ChromeOS tablet device) uses a high-res dual-DSI display
(2500x1500 pixels or so) which is driven by both controllers together to
achieve the required number of lanes to it.

So you end up with one (specific) controller being the master and the
other being the slave, deferring to the master for most everything.
As the controllers are somehow build to work together in that case
via special soc-specific settings.

See [1] for current WIP code, I lifted out of the chromeos kernel and
modified to not have that special rockchip,dual-channel =<&...>; property.
That patch was on the lists already last year I think.

So each dw-mipi-dsi instance needs to at least know that it is in a
master-slave-relationship and right now also needs access to the other
driver instance. Doing the master->slave access should be fine in that
special case, as the IP is the same type.

Also the crtc<->dsi interaction is quite a bit of handling-different between
one crtc talking to 2 DSIs or 2 crtc talking to the 2 DSIs separately.
That's probably the bigger key: to treat them as completely separate
ports means that you get separate CRTCs, IIUC (I'll admit, I'm still a
bit rusty on navigating some DRM concepts).

Brian
_______________________________________________
dri-devel mailing list
dri-devel@lists.freedesktop.org
https://lists.freedesktop.org/mailman/listinfo/dri-devel
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree