Re: [PATCH v2 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

From: Wolfgang Grandegger <hidden>
Date: 2017-03-14 12:11:21
Also in: linux-can, lkml, netdev

Hallo Akshay,

Am 13.03.2017 um 16:38 schrieb Akshay Bhat:
Hi Wolfgang,

On 03/09/2017 12:36 PM, Wolfgang Grandegger wrote:
quoted
Hello,

doing a quick review... I realized a few issues...

Am 17.01.2017 um 20:22 schrieb Akshay Bhat:
... snip ...
quoted
A few other things to check:

Run "cangen" and monitor the message with "candump -e any,0:0,#FFFFFFF".
Then 1) disconnect the cable or 2) short-circuit CAN low and high at the
connector. You should see error messages. After reconnection or removing
the short-circuit (and bus-off recovery) the state should go back to
"active".
With the above sequence, candump reports "ERRORFRAME" with
protocol-violation{{}{acknowledge-slot}}, bus-error. On re-connecting
the cable the can state goes back to ACTIVE and I see the messages that
were in the queue being sent.
Do you get the ACK error also with berr-reporting off? Would be nice if 
you could show a candump log here.

Also, any error message should show the bus error counts in data[7,8]:

http://lxr.free-electrons.com/source/drivers/net/can/sja1000/sja1000.c#L408

And please check bus-off as well (short-circuiting CAN low and high).

Wolfgang.
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help