Thread (1 message) 1 message, 1 author, 2016-02-26
DORMANTno replies

[PATCH V6 09/10] ARM64: tegra: select PM_GENERIC_DOMAINS

From: Jon Hunter <hidden>
Date: 2016-02-26 15:48:43
Also in: linux-pm, linux-tegra
Subsystem: arm64 port (aarch64 architecture), the rest · Maintainers: Catalin Marinas, Will Deacon, Linus Torvalds

Possibly related (same subject, not in this thread)

Enable PM_GENERIC_DOMAINS for tegra 64-bit devices. To ensure that devices
dependent upon a particular power-domain are only probed when that power
domain has been powered up, requires that PM is made mandatory for tegra
64-bit devices and so select this option for tegra as well.

Signed-off-by: Jon Hunter <redacted>
---
 arch/arm64/Kconfig.platforms | 2 ++
 1 file changed, 2 insertions(+)
diff --git a/arch/arm64/Kconfig.platforms b/arch/arm64/Kconfig.platforms
index 1c3a137e216b..bd52c3e80ac5 100644
--- a/arch/arm64/Kconfig.platforms
+++ b/arch/arm64/Kconfig.platforms
@@ -113,6 +113,8 @@ config ARCH_TEGRA
 	select GENERIC_CLOCKEVENTS
 	select HAVE_CLK
 	select PINCTRL
+	select PM
+	select PM_GENERIC_DOMAINS
 	select RESET_CONTROLLER
 	help
 	  This enables support for the NVIDIA Tegra SoC family.
-- 
2.1.4