Thread (26 messages) 26 messages, 3 authors, 2015-09-04

Re: [PATCH 02/13] power: bq24257: Add dead battery reporting

From: Andrew F. Davis <hidden>
Date: 2015-09-01 19:33:11
Also in: linux-pm

On 08/31/2015 09:10 PM, Andreas Dannenberg wrote:
A missing/disconnected battery is now reported as dead rather than an
unspecified failure via the charger's sysfs health property.

$ cat health
Dead
Poor cat :(
quoted hunk ↗ jump to hunk
Signed-off-by: Andreas Dannenberg <redacted>
---
  drivers/power/bq24257_charger.c | 4 ++++
  1 file changed, 4 insertions(+)
diff --git a/drivers/power/bq24257_charger.c b/drivers/power/bq24257_charger.c
index db81356..0b34528 100644
--- a/drivers/power/bq24257_charger.c
+++ b/drivers/power/bq24257_charger.c
@@ -274,6 +274,10 @@ static int bq24257_power_supply_get_property(struct power_supply *psy,
  			val->intval = POWER_SUPPLY_HEALTH_SAFETY_TIMER_EXPIRE;
  			break;

+		case FAULT_NO_BAT:
+			val->intval = POWER_SUPPLY_HEALTH_DEAD;
+			break;
+
I think the best thing to do would be to return -ENODEV as suggested by
power_supply_sysfs.c:305. Also you should probably add the POWER_SUPPLY_PROP_PRESENT
property check and set intval to 0 when there is no battery.

Regards,
Andrew
  		default:
  			val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
  			break;