In the bootloader code enabling the DC-DC is critical. There is a known
issue
which falsely triggers the brownout detection.
quoted
quoted
quoted
Why would the driver not provide these operations?
quoted
quoted
I didn't implement this operation because the suggested workaround for the
hardware issue isn't very nice
(disable brownout detection during enabling DC-DC). I was afraid of the
implementation.
quoted
That doesn't sound too complicated?
Okay, i think i managed the brownout handling.
Unfortunately i'm stuck at the next step. The DC-DC (3 way output) can supply 3
LDOs vddd, vdda, vddio. In case of a DC-DC state change the 3 regulators needs
to be reconfigured before.
I tought of REGULATOR_EVENT_PRE_DISABLE and REGULATOR_EVENT_PRE_ENABLE events,
but i'm not sure that's the right way to achieve a synchronization between DC-DC
and consuming LDOs.
OK, that's possibly sounding a bit complicated. Is it just a case of
writing some value, doing a reconfiguration and rewriting the original
value or is it something more? If it's much more complicated than that
then I think putting a comment in the driver explaining what the issue
is would be the right step, that would address the issue with the driver
looking strange.