On Mon, Jan 05, 2015 at 08:30:05AM -0500, Tejun Heo wrote:
On Mon, Jan 05, 2015 at 03:51:45PM +0530, Suman Tripathi wrote:
quoted
Due to H/W errata, the controller is unable to save the PMP
field fetched from command header before sending the H2D FIS.
When the device returns the PMP port field in the D2H FIS, there is
a mismatch and results in command completion failure. The workaround
is to write the pmp value to PxFBS.DEV field before issuing any command
to PMP.
Signed-off-by: Suman Tripathi <redacted>
Applied 1-2 to libata/for-3.20.
Reverted due to conflicts with the endian fix patches. Please rebase
these two on top of them.
Thanks.
--
tejun