Re: [PATCH v6 1/2] regulator: st-pwm: get voltage and duty table from dts
flat view
From: Doug Anderson <dianders@chromium.org>
Date: 2014-09-24 02:13:13
Also in:
lkml
Chris, On Tue, Sep 23, 2014 at 6:47 PM, Chris Zhong [off-list ref] wrote:
On 09/24/2014 07:43 AM, Doug Anderson wrote:quoted
Chris, On Tue, Sep 23, 2014 at 8:53 AM, Chris Zhong [off-list ref] wrote:quoted
Get voltage & duty table from device tree might be better, other platforms can also use this driver without any modify. Signed-off-by: Chris Zhong <redacted> Reviewed-by: Doug Anderson <dianders@chromium.org>I finally managed to get everything setup and I've now tested this myself on an rk3288-based board. Tested-by: Doug Anderson <dianders@chromium.org> I'd imagine the next step is for Lee to comment on the patch and when he's happy with it Mark Brown will land it? One thing that's still a bit odd (though no different than the behavior of the driver from before you touched it, so it shouldn't block landing IMHO) is that at boot time this regulator will report that it's at the highest voltage but the voltage won't actually change until the first client sets the voltage.Yes, I knew this problem, since the default of duty cycle is 0, not a true value. If we can get duty from pwm, this regulator will report a correct voltage.
I don't think it's possible in all cases to figure out what the voltage was before this regulator was probed. * pin might have been input w/ pullup, pulldown, or no pull * pin might have been driven high or driven low In that case trying to read the duty from the pwm wouldn't make sense. ...but I guess you could add a property to the PWM driver to say that it stays enabled at boot if the FW left it enabled (and keep the same duty cycle / clocks?). That would at least solve the problem where the firmware configured the PWM and left it in a specific state even if it doesn't solve the above problem... -Doug