On 28/06/2013 16:18, Lars-Peter Clausen wrote:
On 06/27/2013 09:26 PM, Alexandre Belloni wrote:
quoted
They are already registered as IIO_TEMP but only implement read_raw. Also,
iio_hwmon_read_val() is using iio_read_channel_processed() and that will
basically only read one of the 2 channels. As I documented, you actually
need to read both channel 8 and channel 9 and then compute the value in
Kelvins. I'm not sure how you want me to do that in the current framework.
What are these two channels actually measuring? Is the value of a single
channel meaningful on it's own? If not it might make sense to update the IIO
driver to just have one temperature channel.
It's not actually meaningful on its own. So, what you would do is expose
one iio channel for two ADC channels and do the computation in read_raw
? or read_processed ? Then using iio-hwon to export it. ?
Regards,
--
Alexandre Belloni, Free Electrons
Embedded Linux, Kernel and Android engineering
http://free-electrons.com