Re: #size-cells = <0> in a bus node, and kernel messages complaining about this
From: Stephen Warren <hidden>
Date: 2012-06-28 22:02:09
On 06/28/2012 02:58 PM, Mitch Bradley wrote:
On 6/28/2012 10:51 AM, Stephen Warren wrote:quoted
On 06/28/2012 02:28 PM, Mitch Bradley wrote:
...
quoted
quoted
Hmmm. 1) The "KERN_ERR "prom_parse: Bad cell count ..." message is presumptuous, if one treats failure of of_translate_address() other than as a hard failure. So if the device naming heuristic were to be improved as suggested above, that message should probably be removed, or at least downgraded to a warning or debug message. 2) of_get_address() also uses OF_CHECK_COUNTS(), which is unhappy with #size-cells == 0. That's not right. #size-cells==0 is perfectly reasonable for enumerated children and should be supported. I'm reasonably certain that the right fix is simply to remove: if (!OF_CHECK_COUNTS(na, ns)) return NULL; from of_get_address(). I looked at all of the places that use of_get_address(). With two exceptions, of_get_address() is followed by of_translate_address(), which will (correctly) fail if #size-cells is 0. The two exceptions are for devices that can only exist below specific buses, which presumably are known to have nonzero #size-cells.There's more needed than that:-( I think of_get_address() still wants to check the address-cells value. Splitting up OF_CHECK_COUNTS as follows: #define OF_CHECK_ADDR_COUNTS(na) ((na) > 0 && (na) <= OF_MAX_ADDR_CELLS) #define OF_CHECK_COUNTS(na, ns) (OF_CHECK_ADDR_COUNTS(na) && (ns) > 0) ... and using OF_CHECK_ADDR_COUNTS in place of OF_CHECK_COUNTS in of_get_address() would allow that.I agree.quoted
However, that still leaves of_device_make_bus_id() calling of_translate_address() in order to generate the device name. That will issue the diagnostic and fall back to the global counter.My suggestion was to eliminate the diagnostic message or downgrade it to warning or debug level. Then the naming heuristic would be: First try of_translate_address() to get a globally-unique address. Failing that, try of_get_address() to get a locally-unique bound address. Failing that, use a counter.
Ah yes. I'd somewhat prefer to avoid calling of_translate_address() when we know it's going to fail though, by passing a parameter to of_device_make_bus_id() indicating whether to use that or of_get_address(). The parameter would be set based on enumerated-bus vs. any other bus type. I coded that locally and it seems to work OK. That way, the diagnostic in of_translate_address() can be left unchanged; it seems like it really is an error.
quoted
It seems like we could make of_device_make_bus_id() call of_get_address() instead of of_translate_address(). However, that would only give the value of the reg property, and not apply the translations all the way to the top of the tree. That in turn means that the following two nodes would be named the same:
...
quoted
But that would still expose us to the same non-unique-name issue if those were enumerated buses: / { container-a { compatible = "enumerated-bus"; ranges = <...>; regulator { reg = <0>; }; }; container-b { compatible = "enumerated-bus"; ranges = <...>; regulator { reg = <0>; }; }; }; Do we need to include the full DT path to an enumerated device, or some other unique data for the node's bus, in the device name of a child of an enumerated bus?I don't know. Is the device name space flat?
Hmmm. It depends on where you look. I end up with /sys/devices/regulators.3/[01].regulator/ this way, the path structure of which is defined by the parent/child device relationship, and implies that device names are relative to their parent. However, device names are treated as a flat namespace in many other places. For example, clocks, regulators, pinctrl settings, etc. are looked up by device name, and the names in the lookup tables are just the device name itself, with no reference to the device's parent.