Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Marc Kleine-Budde <mkl@pengutronix.de>
Date: 2021-10-17 10:34:59
Also in: lkml, netdev

On 30.09.2021 11:33:20, Zhang Changzhong wrote:
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
Applied to linux-can/testing, added stable on Cc.

Thanks,
Marc

-- 