AW: AW: [PATCH] can: isotp: omit unintended hrtimer restart on socket release
From: Sven Schuchmann <hidden>
Date: 2021-08-29 18:28:10
Hello Oliver,
quoted
But I found that this patch decreases the performance of ISO-TP Stack.AFAICS the performance (aka throughput) of the ISO-TP stack is not touched but the grace period when closing an ISO-TP socket is increased.quoted
I have created two testscripts where one plays the server and the other one is running a test and measuring the time how long it takes to transfer an ISO-TP Frame with 1000 Bytes. Without this patch it takes about 35ms to transfer the frame, with this patch it takes about 145ms over vcan0. Anyone an idea on this?Yes. We now syncronize the removal of data structures to prevent a use-after-free issue at socket close time. The synchronize_rcu() call does this job at specific times which leads to this extended time the close() syscall needs to perform.
understood
quoted
bring up a vcan0 interface with: sudo modprobe vcan sudo ip link add dev vcan0 type vcan sudo ifconfig vcan0 up here are the scripts:--- isotp_server.sh ---#!/bin/bash iface=vcan0 echo "Wait for Messages on $iface" while true; do exec 3< <(isotprecv -s 77E -d 714 -b F -p AA:AA $iface) rxpid=$! wait $rxpid output=$(cat <&3) echo "7F 01 11" | isotpsend -s 77E -d 714 -p AA:AA -L 16:8:0 $iface doneIMO the issue arises with the use of isotpsend and isotprecv. These tools are intended to get a hands-on impression how the isotp stack works. This kind of use in a script leads to the creation and (now delayed) *removal* of isotp sockets for *each* single PDU transfer.
Maybe I am wrong but I see something different. e.g. without this patch: (000.000240) canfd0 714 [8] 2B 01 01 01 01 01 01 01 (000.000261) canfd0 77E [8] 30 0F 00 AA AA AA AA AA (000.000496) canfd0 714 [8] 2C 01 01 01 01 01 01 01 and with this patch: (000.000414) canfd0 714 [8] 2B 01 01 01 01 01 01 01 (000.000262) canfd0 77E [8] 30 0F 00 AA AA AA AA AA (000.001536) canfd0 714 [8] 2C 01 01 01 01 01 01 01 So within one PDU transfer the first Consecutive Frame after a Flow Control is taking about 10ms longer (the consecutive frames are sent by ISO-TP Stack here, Tested against a "real" ECU.) So if I transfer a lot of data within one PDU, the more Flow Controls I have and the more "delays" after each FC, and this increases the time for the whole PDU.)
The better approach would be to write a C program that creates ONE socket and simply read() from that socket and write() to it. This should boost your performance even more.
Sure, I do have this. These two scripts are only lets say a "reproducer".
Is the performance a real requirement for your use-case or is this decreased socket close rate a finding which does not really affect your work?
We have a application here which flashes a ECU over CAN according to VW80126. So transferring the data as quick as possible to the ECU is a use-case. Sven