On 9/7/21 6:12 AM, Li Jinlin wrote:
From: Li Jinlin <redacted>
The pending timer has been set up in blk_throtl_init(). However, the
timer is not deleted in blk_throtl_exit(). This means that the timer
handler may still be running after freeing the timer, which would
result in a use-after-free.
Fix by calling del_timer_sync() to delete the timer in blk_throtl_exit().
Applied, thanks.
--
Jens Axboe