Thread (25 messages) 25 messages, 8 authors, 2021-07-02

Re: [PATCH 0/2] blk-mq: fix blk_mq_alloc_request_hctx

flat view

From: Ming Lei <hidden>
Date: 2021-06-30 23:59:45
Also in: linux-nvme

On Wed, Jun 30, 2021 at 09:46:35PM +0200, Hannes Reinecke wrote:
On 6/30/21 8:59 PM, Sagi Grimberg wrote:
quoted
quoted
quoted
quoted
quoted
Shouldn't we rather modify the tagset to only refer to
the current online
CPUs _only_, thereby never submit a connect request for hctx with only
offline CPUs?
Then you may setup very less io queues, and performance may suffer even
though lots of CPUs become online later.
;
Only if we stay with the reduced number of I/O queues. Which is
not what I'm
proposing; I'd rather prefer to connect and disconnect queues
from the cpu
hotplug handler. For starters we could even trigger a reset once
the first
cpu within a hctx is onlined.
Yeah, that need one big/complicated patchset, but not see any advantages
over this simple approach.
I tend to agree with Ming here.
Actually, Daniel and me came to a slightly different idea: use cpu hotplug
notifier.
Thing is, blk-mq already has cpu hotplug notifier, which should ensure that
no I/O is pending during cpu hotplug.
Why should we ensure that for non-managed irq?
If we now add a nvme cpu hotplug notifier which essentially kicks off a
reset once all cpu in a hctx are offline the reset logic will rearrange the
queues to match the current cpu layout.
And when the cpus are getting onlined we'll do another reset.

Daniel is currently preparing a patch; let's see how it goes.
What is the advantage of that big change over this simple way?

Thanks, 
Ming