Re: [PATCH 0/2] blk-mq: fix blk_mq_alloc_request_hctx
flat view
From: Ming Lei <hidden>
Date: 2021-06-30 23:59:45
Also in:
linux-nvme
On Wed, Jun 30, 2021 at 09:46:35PM +0200, Hannes Reinecke wrote:
On 6/30/21 8:59 PM, Sagi Grimberg wrote:quoted
quoted
quoted
quoted
quoted
Shouldn't we rather modify the tagset to only refer to the current online CPUs _only_, thereby never submit a connect request for hctx with only offline CPUs?Then you may setup very less io queues, and performance may suffer even though lots of CPUs become online later. ;Only if we stay with the reduced number of I/O queues. Which is not what I'm proposing; I'd rather prefer to connect and disconnect queues from the cpu hotplug handler. For starters we could even trigger a reset once the first cpu within a hctx is onlined.Yeah, that need one big/complicated patchset, but not see any advantages over this simple approach.I tend to agree with Ming here.Actually, Daniel and me came to a slightly different idea: use cpu hotplug notifier. Thing is, blk-mq already has cpu hotplug notifier, which should ensure that no I/O is pending during cpu hotplug.
Why should we ensure that for non-managed irq?
If we now add a nvme cpu hotplug notifier which essentially kicks off a reset once all cpu in a hctx are offline the reset logic will rearrange the queues to match the current cpu layout. And when the cpus are getting onlined we'll do another reset. Daniel is currently preparing a patch; let's see how it goes.
What is the advantage of that big change over this simple way? Thanks, Ming