On Tue, Oct 20, 2026 at 09:08:08AM +0800, Jisheng Zhang wrote:
On Mon, Oct 19, 2026 at 02:55:14PM +0200, Philipp Zabel wrote:
quoted
On Di, 2026-09-29 at 14:14 +0800, Jisheng Zhang wrote:
quoted
The Synopsys DesignWare I3C master controller can have multiple reset
lines, such as core reset, apb reset, and dma reset.
Update the DT binding documentation to increase maxItems for the resets
property to 2.
The last sentence just listed three reset lines. Why increase to 2?
Per the doc, the last one is dma reset, currently dw I3C driver doesn't support dma.
And increasing it to 3 is still dt compatible. Maybe I misunderstood
something. what's more, I don't have platforms with all 3 resets to test and verify.
If dt maintainers prefer 3 in one step, I will sent out a follow-up patch.
I think you can increase it to 3 globally, then restrict to 1 for the
altera device and 2 for your new one.