Sai,
On 9/28/26 12:00 PM, Judith Mendez wrote:
Hi Sai,
On 9/27/26 10:30 PM, Sai Sree Kartheek Adivi wrote:
quoted
From: Judith Mendez <jm@ti.com>
MMC clock pins must be configured as OUTPUT-only per TRM specification [0]
with receiver disabled (RXACTIVE bit = 0). Change MMC1_CLK from PIN_INPUT
to PIN_OUTPUT in AM64 device trees to match documentation.
There was an issue showing up in automated testing that I was not sure
if it was attributed to this patch series. So I was waiting to see the
error again to debug. Not 100% confident this should go upstream yet.
On top to this, this change also needs to be added for all AM64 based
boards. But as said before, I think we need to wait a bit before
sending this patch (:
~ Judith