On 26-08-24 23:08:57, Jiaxing Hu wrote:
The RK3576 NPU domains need a short settle time after the idle request
is released before the registers behind the domain answer. Without it
the QoS writes that rockchip_pmu_restore_qos() issues land while the
domain is still coming up, and the NPU throws an async SError on the
first cold power-on.
Give rockchip_domain_info an optional delay_us and wait for it between
releasing idle and restoring QoS. Rename DOMAIN_M_O_R_G to
DOMAIN_M_O_R_G_W, since the suffixes name the fields the macro sets and
this one now also carries a wakeup delay; RK3576 is its only user, so
the old spelling is not kept around.
While the macro is being rewritten, give it the regulator argument that
DOMAIN_M_O_R and DOMAIN_M_R already take. Without .need_regulator set,
rockchip_pd_regulator_enable() returns early for every RK3576 domain, so
a domain-supply in the device tree is never looked up and never enabled.
Add a DOMAIN_RK3576_R spelling that passes true and use it for
RK3576_PD_NPU, which is the one RK3576 domain with a rail of its own;
every other domain passes false and is unchanged.
Signed-off-by: Jiaxing Hu <redacted>
Reviewed-by: Abel Vesa <redacted>