Thread (14 messages) 14 messages, 4 authors, 2d ago

Re: [PATCH v8 3/3] thermal/drivers/imx: Add calibration offset support

From: CHENG Haoning (BCSC/ENG1) <hidden>
Date: 2026-07-20 02:10:15
Also in: imx, linux-devicetree, linux-pm, lkml

On 2026-07-17 06:23:44+00:00, CHENG Haoning (BCSC/ENG1) wrote:
On Wed, Jul 15, 2026 at 11:06:07AM +0200, Frieder Schrempf wrote:
quoted
On 14.07.26 12:28, Haoning CHENG via B4 Relay wrote:

Sorry to chime in so late. I just want to understand what this
calibration offset is about. Why would there be a need of a
board-specific offset? The sensor is in the SoC and if you add a
board-specific offset, you no longer measure the SoC core temperature,
right?

How would you determine the offset in the first place? How would I know
what fsl,temp-calibration-offset-millicelsius should be set to? I could
put a sensor on the SoC case and use the delta as offset, but then I
would just account for the thermal resistance of the casing and not
measure the SoC core temperature anymore, right?
Hi Frieder,

Thanks for pointing this out. Your understanding is correct: after
applying the offset, the reported value no longer represents the raw
SoC die or junction temperature.

For this board, the required "SoC temperature" is the package-surface
temperature. The offset was derived by comparing the TEMPMON reading
against a calibrated external sensor placed near the SoC package
surface under steady-state thermal conditions, and is used to
approximate the package-surface temperature from the internal TEMPMON
reading.

The Linux thermal framework does not require a thermal zone to use a
specific temperature reference. It only requires the reported
temperature and trip points to use the same temperature domain.

In this driver, the offset is added in get_temp() and subtracted in
set_alarm() and set_panic() when programming the hardware thresholds.
This keeps the reported temperature and trip points in the same
package-surface temperature domain. Doing this in the driver is
necessary because the hardware alarm thresholds must also be offset-
corrected; applying the offset only in userspace would cause the
TEMPMON IRQ to fire at the wrong die temperature.

I agree that "calibration offset" is misleading, since this does not
calibrate TEMPMON to a more accurate junction temperature. In the next
revision, the commit messages and DT binding have been updated to
describe this as a board-specific conversion offset from the internal
sensor reading to an estimated package-surface temperature.

Thanks,
Haoning
Hi Frieder,

I need to correct my previous reply. After further discussion with our hardware team, the offset does NOT convert die temperature to package-surface temperature.

Their thermal characterization shows that the raw TEMPMON sensor reading itself deviates from the theoretical junction temperature - this deviation exists even at the die level, before any board or package influence. The offset corrects the sensor reading toward the actual junction temperature, so it is a genuine sensor calibration.

Board-level effects may contribute additionally, but they are not the primary reason for this feature. I apologize for the confusion - my earlier description was inaccurate. The v10 series reflects this corrected understanding.

Thanks,
Haoning