Thread (13 messages) 13 messages, 3 authors, 2025-02-27

Re: [PATCH v5 1/9] dt-bindings: mfd: brcm,bcm59056: Convert to YAML

From: Artur Weber <aweber.kernel@gmail.com>
Date: 2025-02-22 10:57:41
Also in: linux-devicetree, lkml

On 22.02.2025 10:43, Krzysztof Kozlowski wrote:
On Fri, Feb 21, 2025 at 09:16:23PM +0100, Artur Weber wrote:
quoted
Convert devicetree bindings for the Broadcom BCM59056 PMU MFD from
TXT to YAML format. This patch does not change any functionality;
the bindings remain the same.

The bindings have been split into two parts: the MFD binding and
a separate binding for the regulator node, to simplify the addition
of other models later (which have different regulators).

Signed-off-by: Artur Weber <aweber.kernel@gmail.com>
---
Changes in v5:
- Replace mfd/brcm,bcm59056.yaml with mfd/brcm,bcm590xx.yaml in
   regulator binding description

Changes in v4:
- Made $ref use full schema path
- Cleaned up example
- Dropped regulator name list comment
- Changed description of regulator binding to mention BCM59056
   explicitly
- Changed "Power Management IC" to "Power Management Unit" to match
   official Broadcom naming
- Renamed mfd/brcm,bcm59056.yaml to mfd/brcm,bcm590xx.yaml
I don't understand why the name became "xx", instead of matching exactly
compatible. It wasn't like this when I reviewed it last time and this is
really unexpected change.

Please follow standard rules: filename must match compatible.
The change was mostly to make it more generic; it felt a bit weird that
the BCM59054 regulator binding (added in the next patch) referenced a
binding named after BCM59056. But if this is not a problem, and a
concrete model number is required (even if it is only one of the
supported devices), then I'll switch back to the bcm59056 name.

Best regards
Artur
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree