Thread (1 message) 1 message, 1 author, 2022-11-16
STALE1351d LANDED: 4 (4M)

Revision v5 of 4 in this series; 1 review trailer; landed in mainline as ad3b7f6141f8 on 2022-12-02.

Revisions (4)
  1. v2 [diff vs current]
  2. v3 [diff vs current]
  3. v4 [diff vs current]
  4. v5 current

[PATCH printk v5 28/40] tty: serial: samsung_tty: use console_is_registered()

From: John Ogness <john.ogness@linutronix.de>
Date: 2022-11-16 16:25:20
Also in: linux-samsung-soc, linux-serial, lkml
Subsystem: arm/samsung s3c, s5p and exynos arm architectures, the rest, tty layer and serial drivers · Maintainers: Krzysztof Kozlowski, Peter Griffin, Linus Torvalds, Greg Kroah-Hartman, Jiri Slaby

It is not reliable to check for CON_ENABLED in order to identify if a
console is registered. Use console_is_registered() instead.

Signed-off-by: John Ogness <john.ogness@linutronix.de>
Reviewed-by: Petr Mladek <pmladek@suse.com>
---
 drivers/tty/serial/samsung_tty.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/tty/serial/samsung_tty.c b/drivers/tty/serial/samsung_tty.c
index 77d1363029f5..9c252c9ca95a 100644
--- a/drivers/tty/serial/samsung_tty.c
+++ b/drivers/tty/serial/samsung_tty.c
@@ -1732,7 +1732,7 @@ static void __init s3c24xx_serial_register_console(void)
 
 static void s3c24xx_serial_unregister_console(void)
 {
-	if (s3c24xx_serial_console.flags & CON_ENABLED)
+	if (console_is_registered(&s3c24xx_serial_console))
 		unregister_console(&s3c24xx_serial_console);
 }
 
-- 
2.30.2


_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel