Re: [PATCH 7/8] hwmon: (scmi) Register explicitly with Thermal Framework
From: Cristian Marussi <cristian.marussi@arm.com>
Date: 2022-10-28 17:13:46
Also in:
linux-hwmon, lkml
On Fri, Oct 28, 2022 at 09:34:05AM -0700, Guenter Roeck wrote:
On 10/28/22 09:15, Cristian Marussi wrote:quoted
On Fri, Oct 28, 2022 at 08:58:58AM -0700, Guenter Roeck wrote:quoted
On 10/28/22 08:35, Cristian Marussi wrote: [ ... ]quoted
quoted
quoted
+ /* + * Try to register a temperature sensor with the Thermal Framework: + * skip sensors not defined as part of any thermal zone (-ENODEV) but + * report any other errors related to misconfigured zones/sensors. + */ + tzd = devm_thermal_of_zone_register(dev, th_sensor->info->id, th_sensor, + &scmi_hwmon_thermal_ops); + if (IS_ERR(tzd)) { + devm_kfree(dev, th_sensor); + + if (PTR_ERR(tzd) != -ENODEV) + return PTR_ERR(tzd); + + dev_info(dev, "Sensor '%s' not attached to any thermal zone.\n", + sensor->name);There were complaints about this message as it is noisy. If you send another version, please drop it unless attaching each sensor to a thermal zone is strongly expected. If you don't send another version, I'll drop it while applying.Ok fine for me. I am waiting to have some feedback from Sudeep too, but I do not have plan for another version as of now. As a side note, though, I understand the 'noisiness' argument, but, sincerely this same message in the original HWMON code was the only reason why I spotted that something was wrong with the SCMI/HWMON interactions and discovered the indexes/ids mismatch...if not for that it would have gone un-noticed that a perfectly configured ThermalZone/Sensor was not working properly... (un-noticed at least until something would have been burnt to fire in my house .. joking :P)Good point. Did you ever check the returned error code ? Maybe we could use it to distinguish "it is not attached to a thermal zone because it is not associated with one" from "attaching to a thermal zone failed because its configuration is bad/incomplete".Yes, it is what I do already indeed, in this regards I mimicked what the hwmon-thermal bridge was doing. In scmi_thermal_sensor_register() this message is printed out only if Thermal registration returned -ENODEV and no err is reported (which means teh specified sensor was not found attached to any TZ), while in the caller of scmi_thermal_sensor_register() for any error returned but -ENOMEM I print: "Thermal zone misconfigured for %s. err=%d\n", since any error reported by Thermal other than ENODEV and ENOMEM means the DT parsing unveiled some configuration anomaly.Ok, then let's hope that this finds misconfigurations and drop the info message.
The mismatch of indexes at hand won't be catched being reported by Thermal as misconfig but just as not found ENODEV. Anyway it is fine for me to drop the message.
I just noticed another problem in your code: + if (ret == -ENOMEM) + return ret; + else if (ret) + dev_warn(dev, + "Thermal zone misconfigured for %s. err=%d\n", + sensor->name, ret); Static analyzers will rightfully notice that else after return is unnecessary. Please rewrite and drop the else. I think something like
Ah yes...my bad.
if (ret) {
if (ret == -ENOMEM)
return ret;
dev_warn(dev,
"Thermal zone misconfigured for %s. err=%d\n",
sensor->name, ret);
}
would be better since ret would only be evaluated once in the no-error case.I'll resend this one with the fix and the dropped message. Thanks, Cristian _______________________________________________ linux-arm-kernel mailing list linux-arm-kernel@lists.infradead.org http://lists.infradead.org/mailman/listinfo/linux-arm-kernel