The fixed regulator clock name has a unit address, but no reg property,
which generates a warning in DTC. Change its name to remove its useless
unit address.
Signed-off-by: Maxime Ripard <redacted>
---
arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts b/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts
index 7ef96f9ff7ae..6a4af14718f5 100644
--- a/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts
+++ b/arch/arm64/boot/dts/allwinner/sun50i-a64-pinetab.dts
@@ -77,7 +77,7 @@ speaker_amp: audio-amplifier {
sound-name-prefix = "Speaker Amp";
};
- vdd_bl: regulator@0 {
+ vdd_bl: regulator {
compatible = "regulator-fixed";
regulator-name = "bl-3v3";
regulator-min-microvolt = <3300000>;--
2.31.1