Thread (6 messages) 6 messages, 2 authors, 2021-06-24

Re: [PATCH 2/2] dt-bindings: opp: Convert to DT schema

From: Viresh Kumar <viresh.kumar@linaro.org>
Date: 2021-06-24 04:32:56
Also in: dri-devel, linux-devicetree, linux-pm, lkml

Thanks for taking it up :)

On 23-06-21, 17:07, Rob Herring wrote:
quoted hunk ↗ jump to hunk
diff --git a/Documentation/devicetree/bindings/opp/opp-v2-base.yaml b/Documentation/devicetree/bindings/opp/opp-v2-base.yaml
+$id: http://devicetree.org/schemas/opp/opp-v2-base.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Generic OPP (Operating Performance Points) Common Binding
+
+maintainers:
+  - Viresh Kumar <viresh.kumar@linaro.org>
+
+description: |
+  Devices work at voltage-current-frequency combinations and some implementations
+  have the liberty of choosing these. These combinations are called Operating
+  Performance Points aka OPPs. This document defines bindings for these OPPs
+  applicable across wide range of devices. For illustration purpose, this document
+  uses CPU as a device.
+
+  This describes the OPPs belonging to a device.
+
+select: false
+
+properties:
+  $nodename:
+    pattern: '^opp-table(-[a-z0-9]+)?$'
+
+  opp-shared:
+    description:
+      Indicates that device nodes using this OPP Table Node's phandle switch
+      their DVFS state together, i.e. they share clock/voltage/current lines.
+      Missing property means devices have independent clock/voltage/current
+      lines, but they share OPP tables.
+    type: boolean
+
+patternProperties:
+  '^opp-?[0-9]+$':
+    type: object
+    description:
+      One or more OPP nodes describing voltage-current-frequency combinations.
+      Their name isn't significant but their phandle can be used to reference an
+      OPP. These are mandatory except for the case where the OPP table is
+      present only to indicate dependency between devices using the opp-shared
+      property.
+
+    properties:
+      opp-hz:
+        description:
+          Frequency in Hz, expressed as a 64-bit big-endian integer. This is a
+          required property for all device nodes, unless another "required"
+          property to uniquely identify the OPP nodes exists. Devices like power
+          domains must have another (implementation dependent) property.
+
+      opp-peak-kBps:
+        description:
+          Peak bandwidth in kilobytes per second, expressed as an array of
+          32-bit big-endian integers. Each element of the array represents the
+          peak bandwidth value of each interconnect path. The number of elements
+          should match the number of interconnect paths.
+        minItems: 1
+        maxItems: 32  # Should be enough
Can we move this down, closer to opp-avg-kBps ?
+
+      opp-microvolt:
+        description: |
+          Voltage for the OPP
+
+          A single regulator's voltage is specified with an array of size one or three.
+          Single entry is for target voltage and three entries are for <target min max>
+          voltages.
+
+          Entries for multiple regulators shall be provided in the same field separated
+          by angular brackets <>. The OPP binding doesn't provide any provisions to
+          relate the values to their power supplies or the order in which the supplies
+          need to be configured and that is left for the implementation specific
+          binding.
+
+          Entries for all regulators shall be of the same size, i.e. either all use a
+          single value or triplets.
+        minItems: 1
+        maxItems: 8
For consistency with rest of the doc, maybe add

# Should be enough regulators
+        items:
+          minItems: 1
+          maxItems: 3
+
+      opp-microamp:
+        description: |
+          The maximum current drawn by the device in microamperes considering
+          system specific parameters (such as transients, process, aging,
+          maximum operating temperature range etc.) as necessary. This may be
+          used to set the most efficient regulator operating mode.
+
+          Should only be set if opp-microvolt(-name)? is set for the OPP.
What is the significance of '?' here ?
+
+          Entries for multiple regulators shall be provided in the same field
+          separated by angular brackets <>. If current values aren't required
+          for a regulator, then it shall be filled with 0. If current values
+          aren't required for any of the regulators, then this field is not
+          required. The OPP binding doesn't provide any provisions to relate the
+          values to their power supplies or the order in which the supplies need
+          to be configured and that is left for the implementation specific
+          binding.
+        minItems: 1
+        maxItems: 8   # Should be enough regulators
+        items:
+          minItems: 1
+          maxItems: 3
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>

-- 
viresh

_______________________________________________