Thread (12 messages) flat view 12 messages, 4 authors, 2021-06-01
STALE1901d

[PATCH 0/4] soc: xilinx: pm_domains: cleanup and fix PM_INIT_FINALIZE

From: Michael Tretter <m.tretter@pengutronix.de>
Date: 2021-03-17 16:05:47

Hi,

Patch 1 of this series fixes the ZynqMP PMU FW power management
initialization, which was done by the wrong driver. PM_INIT_FINALIZE must be
called from the zynqmp_pm_domains driver, which handles power domains, instead
of the zynmp_power driver, which is responsible for suspend and shutdown.

Patches 2 to 4 are various cleanup patches to improve the readability and
debugging experience of the zynqmp_pm_domains driver.

Michael

Michael Tretter (4):
  soc: xilinx: move PM_INIT_FINALIZE to zynqmp_pm_domains driver
  soc: xilinx: cleanup debug and error messages
  soc: xilinx: use a properly named field instead of flags
  soc: xilinx: add a to_zynqmp_pm_domain macro

 drivers/soc/xilinx/zynqmp_pm_domains.c | 79 +++++++++++++-------------
 drivers/soc/xilinx/zynqmp_power.c      |  1 -
 2 files changed, 38 insertions(+), 42 deletions(-)

-- 
2.29.2


_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel