Re: [PATCH] counter: stm32-lptimer-cnt: remove iio counter abi
From: William Breathitt Gray <hidden>
Date: 2021-01-29 08:36:55
On Fri, Jan 22, 2021 at 04:03:23PM +0100, Fabrice Gasnier wrote:
Currently, the STM32 LP Timer counter driver registers into both IIO and counter subsystems, which is redundant. Remove the IIO counter ABI and IIO registration from the STM32 LP Timer counter driver since it's been superseded by the Counter subsystem as discussed in [1]. Keep only the counter subsystem related part. Move a part of the ABI documentation into a driver comment. This also removes a duplicate ABI warning $ scripts/get_abi.pl validate ... /sys/bus/iio/devices/iio:deviceX/in_count0_preset is defined 2 times: ./Documentation/ABI/testing/sysfs-bus-iio-timer-stm32:100 ./Documentation/ABI/testing/sysfs-bus-iio-lptimer-stm32:0 [1] https://lkml.org/lkml/2021/1/19/347 Signed-off-by: Fabrice Gasnier <fabrice.gasnier@foss.st.com> --- .../ABI/testing/sysfs-bus-iio-lptimer-stm32 | 62 ----- drivers/counter/stm32-lptimer-cnt.c | 297 +++------------------ 2 files changed, 36 insertions(+), 323 deletions(-) delete mode 100644 Documentation/ABI/testing/sysfs-bus-iio-lptimer-stm32
Hi Fabrice, I noticed this is missing a Kconfig change to remove the IIO dependency from the STM32_LPTIMER_CNT config option. I assume that dependency is no longer necessary with the IIO code is removed. William Breathitt Gray