On Thu, Oct 8, 2020 at 5:48 PM Arnd Bergmann [off-list ref] wrote:
The heartbeat functionality is mostly separate from the
actual timer interrupt handling, and it is only used on
five platforms.
Split it out into a separate function and call that directly
from the timer irq on those platforms.
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Reviewed-by: Geert Uytterhoeven <geert@linux-m68k.org>
Acked-by: Geert Uytterhoeven <geert@linux-m68k.org>
And finally (for Amiga):
Tested-by: Geert Uytterhoeven <geert@linux-m68k.org>
Gr{oetje,eeting}s,
Geert
--