Hi Vasily,
quoted
maybe just the read sync train params command is broken? Can you change the init code and not send it and see if the rest of the init phase proceeds. I would rather have the secure connections actually tested before dismissing it altogether.
I don't think that I have any devices that support secure connections
to test, I've got only a bluetooth mouse and headphones, both are from
the 2.0 era.
FWIW unofficial recommendation from Realtek to Pine64 was to avoid
using any 4.1+ features on this chip. Unfortunately I don't have any
contacts with Realtek, so I can't confirm that.
quoted
Mind you, there were broken Broadcom implementation of connectionless slave broadcast as well. Maybe this is similar.
I'd prefer to stick to what works unless there's some comprehensive
test that can figure out what's broken.
check if removing the read sync trains params command makes the controller initialize and usable. Then we see about the rest.
Regards
Marcel
_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel