On 二, 2019-06-25 at 10:53 -0300, Mauro Carvalho Chehab wrote:
Em Tue, 25 Jun 2019 21:40:11 +0800
Zhang Rui [off-list ref] escreveu:
quoted
On 二, 2019-06-18 at 18:05 -0300, Mauro Carvalho Chehab wrote:
quoted
Rename the thermal documentation files to ReST, add an
index for them and adjust in order to produce a nice html
output via the Sphinx build system.

At its new index.rst, let's add a :orphan: while this is not
linked
to
the main index.rst file, in order to avoid build warnings.

Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
  
Acked-by: Zhang Rui <rui.zhang@intel.com>

should I apply this patch or you have a separate tree for all these
changes?
Feel free to apply it directly to your tree. The patches on this
series are pretty much independent.
okay, queued for 5.3-rc1.

thanks,
rui
quoted

thanks,
rui
quoted
---
 ...pu-cooling-api.txt => cpu-cooling-api.rst} |  39 +-
 .../{exynos_thermal => exynos_thermal.rst}    |  47 +-
 ...emulation => exynos_thermal_emulation.rst} |  66 +--
 Documentation/thermal/index.rst               |  18 +
 ...el_powerclamp.txt => intel_powerclamp.rst} | 177 +++----
 .../{nouveau_thermal => nouveau_thermal.rst}  |  54 +-
 ...ower_allocator.txt => power_allocator.rst} | 140 ++---
 .../thermal/{sysfs-api.txt => sysfs-api.rst}  | 490
++++++++++++--
----
 ...hermal => x86_pkg_temperature_thermal.rst} |  28 +-
 MAINTAINERS                                   |   2 +-
 include/linux/thermal.h                       |   4 +-
 11 files changed, 665 insertions(+), 400 deletions(-)
 rename Documentation/thermal/{cpu-cooling-api.txt => cpu-
cooling-
api.rst} (82%)
 rename Documentation/thermal/{exynos_thermal =>
exynos_thermal.rst}
(67%)
 rename Documentation/thermal/{exynos_thermal_emulation =>
exynos_thermal_emulation.rst} (36%)
 create mode 100644 Documentation/thermal/index.rst
 rename Documentation/thermal/{intel_powerclamp.txt =>
intel_powerclamp.rst} (76%)
 rename Documentation/thermal/{nouveau_thermal =>
nouveau_thermal.rst} (64%)
 rename Documentation/thermal/{power_allocator.txt =>
power_allocator.rst} (74%)
 rename Documentation/thermal/{sysfs-api.txt => sysfs-api.rst}
(66%)
 rename Documentation/thermal/{x86_pkg_temperature_thermal =>
x86_pkg_temperature_thermal.rst} (80%)
diff --git a/Documentation/thermal/cpu-cooling-api.txt
b/Documentation/thermal/cpu-cooling-api.rst
similarity index 82%
rename from Documentation/thermal/cpu-cooling-api.txt
rename to Documentation/thermal/cpu-cooling-api.rst
index 7df567eaea1a..645d914c45a6 100644
--- a/Documentation/thermal/cpu-cooling-api.txt
+++ b/Documentation/thermal/cpu-cooling-api.rst
@@ -1,5 +1,6 @@
+=======================
 CPU cooling APIs How To
-===================================
+=======================
 
 Written by Amit Daniel Kachhap [off-list ref]
 
@@ -8,40 +9,54 @@ Updated: 6 Jan 2015
 Copyright (c)  2012 Samsung Electronics Co., Ltd(http://www.sams
ung.
com)
 
 0. Introduction
+===============
 
 The generic cpu cooling(freq clipping) provides
registration/unregistration APIs
 to the caller. The binding of the cooling devices to the trip
point
is left for
 the user. The registration APIs returns the cooling device
pointer.
 
 1. cpu cooling APIs
+===================
 
 1.1 cpufreq registration/unregistration APIs
-1.1.1 struct thermal_cooling_device *cpufreq_cooling_register(
-	struct cpumask *clip_cpus)
+--------------------------------------------
+
+    ::
+
+	struct thermal_cooling_device
+	*cpufreq_cooling_register(struct cpumask *clip_cpus)
 
     This interface function registers the cpufreq cooling device
with the name
     "thermal-cpufreq-%x". This api can support multiple
instances of
cpufreq
     cooling devices.
 
-   clip_cpus: cpumask of cpus where the frequency constraints
will
happen.
+   clip_cpus:
+	cpumask of cpus where the frequency constraints will
happen.
 
-1.1.2 struct thermal_cooling_device
*of_cpufreq_cooling_register(
-					struct cpufreq_policy
*policy)
+    ::
+
+	struct thermal_cooling_device
+	*of_cpufreq_cooling_register(struct cpufreq_policy
*policy)
 
     This interface function registers the cpufreq cooling device
with
     the name "thermal-cpufreq-%x" linking it with a device tree
node, in
     order to bind it via the thermal DT code. This api can
support
multiple
     instances of cpufreq cooling devices.
 
-    policy: CPUFreq policy.
+    policy:
+	CPUFreq policy.
 
-1.1.3 void cpufreq_cooling_unregister(struct
thermal_cooling_device
*cdev)
+
+    ::
+
+	void cpufreq_cooling_unregister(struct
thermal_cooling_device *cdev)
 
     This interface function unregisters the "thermal-cpufreq-%x"
cooling device.
 
     cdev: Cooling device pointer which has to be unregistered.
 
 2. Power models
+===============
 
 The power API registration functions provide a simple power
model
for
 CPUs.  The current power is calculated as dynamic power (static
power isn't
@@ -65,9 +80,9 @@ For a given processor implementation the
primary
factors are:
   variation.  In pathological cases this variation can be
significant,
   but typically it is of a much lesser impact than the factors
above.
 
-A high level dynamic power consumption model may then be
represented
as:
+A high level dynamic power consumption model may then be
represented
as::
 
-Pdyn = f(run) * Voltage^2 * Frequency * Utilisation
+	Pdyn = f(run) * Voltage^2 * Frequency * Utilisation
 
 f(run) here represents the described execution behaviour and its
 result has a units of Watts/Hz/Volt^2 (this often expressed in
@@ -80,9 +95,9 @@ factors.  Therefore, in initial implementation
that
contribution is
 represented as a constant coefficient.  This is a simplification
 consistent with the relative contribution to overall power
variation.
 
-In this simplified representation our model becomes:
+In this simplified representation our model becomes::
 
-Pdyn = Capacitance * Voltage^2 * Frequency * Utilisation
+	Pdyn = Capacitance * Voltage^2 * Frequency * Utilisation
 
 Where `capacitance` is a constant that represents an indicative
 running time dynamic power coefficient in fundamental units of
diff --git a/Documentation/thermal/exynos_thermal
b/Documentation/thermal/exynos_thermal.rst
similarity index 67%
rename from Documentation/thermal/exynos_thermal
rename to Documentation/thermal/exynos_thermal.rst
index 9010c4416967..5bd556566c70 100644
--- a/Documentation/thermal/exynos_thermal
+++ b/Documentation/thermal/exynos_thermal.rst
@@ -1,8 +1,11 @@
+========================
 Kernel driver exynos_tmu
-=================
+========================
 
 Supported chips:
+
 * ARM SAMSUNG EXYNOS4, EXYNOS5 series of SoC
+
   Datasheet: Not publicly available
 
 Authors: Donggeun Kim [off-list ref]
@@ -19,32 +22,39 @@ Temperature can be taken from the temperature
code.
 There are three equations converting from temperature to
temperature
code.
 
 The three equations are:
-  1. Two point trimming
+  1. Two point trimming::
+
 	Tc = (T - 25) * (TI2 - TI1) / (85 - 25) + TI1
 
-  2. One point trimming
+  2. One point trimming::
+
 	Tc = T + TI1 - 25
 
-  3. No trimming
+  3. No trimming::
+
 	Tc = T + 50
 
-  Tc: Temperature code, T: Temperature,
-  TI1: Trimming info for 25 degree Celsius (stored at TRIMINFO
register)
+  Tc:
+       Temperature code, T: Temperature,
+  TI1:
+       Trimming info for 25 degree Celsius (stored at TRIMINFO
register)
        Temperature code measured at 25 degree Celsius which is
unchanged
-  TI2: Trimming info for 85 degree Celsius (stored at TRIMINFO
register)
+  TI2:
+       Trimming info for 85 degree Celsius (stored at TRIMINFO
register)
        Temperature code measured at 85 degree Celsius which is
unchanged
 
 TMU(Thermal Management Unit) in EXYNOS4/5 generates interrupt
 when temperature exceeds pre-defined levels.
 The maximum number of configurable threshold is five.
-The threshold levels are defined as follows:
+The threshold levels are defined as follows::
+
   Level_0: current temperature > trigger_level_0 + threshold
   Level_1: current temperature > trigger_level_1 + threshold
   Level_2: current temperature > trigger_level_2 + threshold
   Level_3: current temperature > trigger_level_3 + threshold
 
-  The threshold and each trigger_level are set
-  through the corresponding registers.
+The threshold and each trigger_level are set
+through the corresponding registers.
 
 When an interrupt occurs, this driver notify kernel thermal
framework
 with the function exynos_report_trigger.
@@ -54,24 +64,27 @@ it can be used to synchronize the cooling
action.
 TMU driver description:
 -----------------------
 
-The exynos thermal driver is structured as,
+The exynos thermal driver is structured as::
 
 					Kernel Core thermal
framework
 				(thermal_core.c, step_wise.c,
cpu_cooling.c)
 								
^
 								
|
 								
|
-TMU configuration data -------> TMU Driver  <------> Exynos Core
thermal wrapper
-(exynos_tmu_data.c)	      (exynos_tmu.c)	   (exyno
s_th
ermal_common.c)
-(exynos_tmu_data.h)	      (exynos_tmu.h)	   (exyno
s_th
ermal_common.h)
+  TMU configuration data -----> TMU Driver  <----> Exynos Core
thermal wrapper
+  (exynos_tmu_data.c)	      (exynos_tmu.c)	   (exy
nos_
thermal_common.c)
+  (exynos_tmu_data.h)	      (exynos_tmu.h)	   (exy
nos_
thermal_common.h)
 
-a) TMU configuration data: This consist of TMU register
offsets/bitfields
+a) TMU configuration data:
+		This consist of TMU register offsets/bitfields
 		described through structure
exynos_tmu_registers.
Also several
 		other platform data (struct
exynos_tmu_platform_data) members
 		are used to configure the TMU.
-b) TMU driver: This component initialises the TMU controller and
sets different
+b) TMU driver:
+		This component initialises the TMU controller
and
sets different
 		thresholds. It invokes core thermal
implementation
with the call
 		exynos_report_trigger.
-c) Exynos Core thermal wrapper: This provides 3 wrapper function
to
use the
+c) Exynos Core thermal wrapper:
+		This provides 3 wrapper function to use the
 		Kernel core thermal framework. They are
exynos_unregister_thermal,
 		exynos_register_thermal and
exynos_report_trigger.
diff --git a/Documentation/thermal/exynos_thermal_emulation
b/Documentation/thermal/exynos_thermal_emulation.rst
similarity index 36%
rename from Documentation/thermal/exynos_thermal_emulation
rename to Documentation/thermal/exynos_thermal_emulation.rst
index b15efec6ca28..c21d10838bc5 100644
--- a/Documentation/thermal/exynos_thermal_emulation
+++ b/Documentation/thermal/exynos_thermal_emulation.rst
@@ -1,5 +1,6 @@
-EXYNOS EMULATION MODE
-========================
+=====================
+Exynos Emulation Mode
+=====================
 
 Copyright (C) 2012 Samsung Electronics
 
@@ -8,46 +9,53 @@ Written by Jonghwa Lee <jonghwa3.lee@samsung.co
m>
 Description
 -----------
 
-Exynos 4x12 (4212, 4412) and 5 series provide emulation mode for
thermal management unit.
-Thermal emulation mode supports software debug for TMU's
operation.
User can set temperature
-manually with software code and TMU will read current
temperature
from user value not from
-sensor's value.
+Exynos 4x12 (4212, 4412) and 5 series provide emulation mode for
thermal
+management unit. Thermal emulation mode supports software debug
for
+TMU's operation. User can set temperature manually with software
code
+and TMU will read current temperature from user value not from
sensor's
+value.
 
-Enabling CONFIG_THERMAL_EMULATION option will make this support
available.
-When it's enabled, sysfs node will be created as
+Enabling CONFIG_THERMAL_EMULATION option will make this support
+available. When it's enabled, sysfs node will be created as
 /sys/devices/virtual/thermal/thermal_zone'zone id'/emul_temp.
 
-The sysfs node, 'emul_node', will contain value 0 for the
initial
state. When you input any
-temperature you want to update to sysfs node, it automatically
enable emulation mode and
-current temperature will be changed into it.
-(Exynos also supports user changeable delay time which would be
used
to delay of
- changing temperature. However, this node only uses same delay
of
real sensing time, 938us.)
+The sysfs node, 'emul_node', will contain value 0 for the
initial
state.
+When you input any temperature you want to update to sysfs node,
it
+automatically enable emulation mode and current temperature will
be
+changed into it.
 
-Exynos emulation mode requires synchronous of value changing and
enabling. It means when you
-want to update the any value of delay or next temperature, then
you
have to enable emulation
-mode at the same time. (Or you have to keep the mode enabling.)
If
you don't, it fails to
-change the value to updated one and just use last succeessful
value
repeatedly. That's why
-this node gives users the right to change termerpature only.
Just
one interface makes it more
-simply to use.
+(Exynos also supports user changeable delay time which would be
used
to
+delay of changing temperature. However, this node only uses same
delay
+of real sensing time, 938us.)
+
+Exynos emulation mode requires synchronous of value changing and
+enabling. It means when you want to update the any value of
delay or
+next temperature, then you have to enable emulation mode at the
same
+time. (Or you have to keep the mode enabling.) If you don't, it
fails to
+change the value to updated one and just use last succeessful
value
+repeatedly. That's why this node gives users the right to change
+termerpature only. Just one interface makes it more simply to
use.
 
 Disabling emulation mode only requires writing value 0 to sysfs
node.
 
+::
 
-TEMP	120 |
+
+  TEMP	120 |
 	    |
 	100 |
 	    |
 	 80 |
-	    |		     	 	 +-----------
-	 60 |      		     	 |	    |
-	    |	           +-------------|          |
+	    |				 +-----------
+	 60 |      			 |	    |
+	    |		   +-------------|          |
 	 40 |              |         	 |          |
-	    |		   |	     	 |        
  |
-	 20 |		   |	     	 |        
  +-
---------
-	    |	 	   |	     	 |       
   |
          |
+	    |		   |		 |          |
+	 20 |		   |		 |          +
----
------
+	    |		   |		 |          |  
    
    |
 	  0
quoted
______________|_____________|__________|__________|_________
-		   A	    	 A	    A	 
  	
       A     TIME
+		   A		 A	    A		
 
      A     TIME
 		   |<----->|	 |<----->|  |<----->|	
   
    |
 		   | 938us |  	 |	 |  |       |   
    
   |
-emulation    :  0  50	   |  	 70      |  20      |
    
      0
-current temp :   sensor   50		 70         20	
  
    sensor
+  emulation   : 0  50	   |  	 70      |  20      |
    
      0
+  current temp:   sensor   50		 70         20	
 
     sensor
diff --git a/Documentation/thermal/index.rst
b/Documentation/thermal/index.rst
new file mode 100644
index 000000000000..8c1c00146cad
--- /dev/null
+++ b/Documentation/thermal/index.rst
@@ -0,0 +1,18 @@
+:orphan:
+
+=======
+Thermal
+=======
+
+.. toctree::
+   :maxdepth: 1
+
+   cpu-cooling-api
+   sysfs-api
+   power_allocator
+
+   exynos_thermal
+   exynos_thermal_emulation
+   intel_powerclamp
+   nouveau_thermal
+   x86_pkg_temperature_thermal
diff --git a/Documentation/thermal/intel_powerclamp.txt
b/Documentation/thermal/intel_powerclamp.rst
similarity index 76%
rename from Documentation/thermal/intel_powerclamp.txt
rename to Documentation/thermal/intel_powerclamp.rst
index b5df21168fbc..3f6dfb0b3ea6 100644
--- a/Documentation/thermal/intel_powerclamp.txt
+++ b/Documentation/thermal/intel_powerclamp.rst
@@ -1,10 +1,13 @@
-			 =======================
-			 INTEL POWERCLAMP DRIVER
-			 =======================
-By: Arjan van de Ven <arjan@linux.intel.com>
-    Jacob Pan <jacob.jun.pan@linux.intel.com>
+=======================
+Intel Powerclamp Driver
+=======================
+
+By:
+  - Arjan van de Ven <arjan@linux.intel.com>
+  - Jacob Pan <jacob.jun.pan@linux.intel.com>
+
+.. Contents:
 
-Contents:
 	(*) Introduction
 	    - Goals and Objectives
 
@@ -23,7 +26,6 @@ Contents:
 	    - Generic Thermal Layer (sysfs)
 	    - Kernel APIs (TBD)
 
-============
 INTRODUCTION
 ============
 
@@ -47,7 +49,6 @@ scalability, and user experience. In many
cases,
clear advantage is
 shown over taking the CPU offline or modulating the CPU clock.
 
 
-===================
 THEORY OF OPERATION
 ===================
 
@@ -57,11 +58,12 @@ Idle Injection
 On modern Intel processors (Nehalem or later), package level C-
state
 residency is available in MSRs, thus also available to the
kernel.
 
-These MSRs are:
-      #define MSR_PKG_C2_RESIDENCY	0x60D
-      #define MSR_PKG_C3_RESIDENCY	0x3F8
-      #define MSR_PKG_C6_RESIDENCY	0x3F9
-      #define MSR_PKG_C7_RESIDENCY	0x3FA
+These MSRs are::
+
+      #define MSR_PKG_C2_RESIDENCY      0x60D
+      #define MSR_PKG_C3_RESIDENCY      0x3F8
+      #define MSR_PKG_C6_RESIDENCY      0x3F9
+      #define MSR_PKG_C7_RESIDENCY      0x3FA
 
 If the kernel can also inject idle time to the system, then a
 closed-loop control system can be established that manages
package
@@ -96,19 +98,21 @@ are not masked. Tests show that the extra
wakeups
from scheduler tick
 have a dramatic impact on the effectiveness of the powerclamp
driver
 on large scale systems (Westmere system with 80 processors).
 
-CPU0
-		  ____________          ____________
-kidle_inject/0   |   sleep    |  mwait |  sleep     |
-	_________|            |________|            |_______
-			       duration
-CPU1
-		  ____________          ____________
-kidle_inject/1   |   sleep    |  mwait |  sleep     |
-	_________|            |________|            |_______
-			      ^
-			      |
-			      |
-			      roundup(jiffies, interval)
+::
+
+  CPU0
+		    ____________          ____________
+  kidle_inject/0   |   sleep    |  mwait |  sleep     |
+	  _________|            |________|            |_______
+				 duration
+  CPU1
+		    ____________          ____________
+  kidle_inject/1   |   sleep    |  mwait |  sleep     |
+	  _________|            |________|            |_______
+				^
+				|
+				|
+				roundup(jiffies, interval)
 
 Only one CPU is allowed to collect statistics and update global
 control parameters. This CPU is referred to as the controlling
CPU
in
@@ -148,7 +152,7 @@ b) determine the amount of compensation
needed at
each target ratio
 
 Compensation to each target ratio consists of two parts:
 
-        a) steady state error compensation
+	a) steady state error compensation
 	This is to offset the error occurring when the system
can
 	enter idle without extra wakeups (such as external
interrupts).
 
@@ -158,41 +162,42 @@ Compensation to each target ratio consists
of
two parts:
 	slowing down CPU activities.
 
 A debugfs file is provided for the user to examine compensation
-progress and results, such as on a Westmere system.
-[jacob@nex01 ~]$ cat
-/sys/kernel/debug/intel_powerclamp/powerclamp_calib
-controlling cpu: 0
-pct confidence steady dynamic (compensation)
-0	0	0	0
-1	1	0	0
-2	1	1	0
-3	3	1	0
-4	3	1	0
-5	3	1	0
-6	3	1	0
-7	3	1	0
-8	3	1	0
-...
-30	3	2	0
-31	3	2	0
-32	3	1	0
-33	3	2	0
-34	3	1	0
-35	3	2	0
-36	3	1	0
-37	3	2	0
-38	3	1	0
-39	3	2	0
-40	3	3	0
-41	3	1	0
-42	3	2	0
-43	3	1	0
-44	3	1	0
-45	3	2	0
-46	3	3	0
-47	3	0	0
-48	3	2	0
-49	3	3	0
+progress and results, such as on a Westmere system::
+
+  [jacob@nex01 ~]$ cat
+  /sys/kernel/debug/intel_powerclamp/powerclamp_calib
+  controlling cpu: 0
+  pct confidence steady dynamic (compensation)
+  0       0       0       0
+  1       1       0       0
+  2       1       1       0
+  3       3       1       0
+  4       3       1       0
+  5       3       1       0
+  6       3       1       0
+  7       3       1       0
+  8       3       1       0
+  ...
+  30      3       2       0
+  31      3       2       0
+  32      3       1       0
+  33      3       2       0
+  34      3       1       0
+  35      3       2       0
+  36      3       1       0
+  37      3       2       0
+  38      3       1       0
+  39      3       2       0
+  40      3       3       0
+  41      3       1       0
+  42      3       2       0
+  43      3       1       0
+  44      3       1       0
+  45      3       2       0
+  46      3       3       0
+  47      3       0       0
+  48      3       2       0
+  49      3       3       0
 
 Calibration occurs during runtime. No offline method is
available.
 Steady state compensation is used only when confidence levels of
all
@@ -217,9 +222,8 @@ keeps track of clamping kernel threads, even
after they are migrated
 to other CPUs, after a CPU offline event.
 
 
-=====================
 Performance Analysis
-=====================
+====================
 This section describes the general performance data collected on
 multiple systems, including Westmere (80P) and Ivy Bridge (4P,
8P).
 
@@ -257,16 +261,15 @@ achieve up to 40% better performance per
watt.
(measured by a spin
 counter summed over per CPU counting threads spawned for all
running
 CPUs).
 
-====================
 Usage and Interfaces
 ====================
 The powerclamp driver is registered to the generic thermal layer
as
a
-cooling device. Currently, it’s not bound to any thermal zones.
+cooling device. Currently, it’s not bound to any thermal zones::
 
-jacob@chromoly:/sys/class/thermal/cooling_device14$ grep . *
-cur_state:0
-max_state:50
-type:intel_powerclamp
+  jacob@chromoly:/sys/class/thermal/cooling_device14$ grep . *
+  cur_state:0
+  max_state:50
+  type:intel_powerclamp
 
 cur_state allows user to set the desired idle percentage.
Writing 0
to
 cur_state will stop idle injection. Writing a value between 1
and
@@ -278,9 +281,9 @@ cur_state returns value -1 instead of 0 which
is
to avoid confusing
 100% busy state with the disabled state.
 
 Example usage:
-- To inject 25% idle time
-$ sudo sh -c "echo 25 >
/sys/class/thermal/cooling_device80/cur_state
-"
+- To inject 25% idle time::
+
+	$ sudo sh -c "echo 25 >
/sys/class/thermal/cooling_device80/cur_state
 
 If the system is not busy and has more than 25% idle time
already,
 then the powerclamp driver will not start idle injection. Using
Top
@@ -292,23 +295,23 @@ idle time is accounted as normal idle in
that
common code path is
 taken as the idle task.
 
 In this example, 24.1% idle is shown. This helps the system
admin or
-user determine the cause of slowdown, when a powerclamp driver
is in
action.
+user determine the cause of slowdown, when a powerclamp driver
is in
action::
 
 
-Tasks: 197 total,   1 running, 196 sleeping,   0 stopped,   0
zombie
-Cpu(s): 71.2%us,  4.7%sy,  0.0%ni,
24.1%id,  0.0%wa,  0.0%hi,  0.0%si,  0.0%st
-Mem:   3943228k total,  1689632k used,  2253596k free,    74960k
buffers
-Swap:  4087804k total,        0k used,  4087804k free,   945336k
cached
+  Tasks: 197 total,   1 running, 196 sleeping,   0 stopped,   0
zombie
+  Cpu(s): 71.2%us,  4.7%sy,  0.0%ni,
24.1%id,  0.0%wa,  0.0%hi,  0.0%si,  0.0%st
+  Mem:   3943228k total,  1689632k used,  2253596k
free,    74960k
buffers
+  Swap:  4087804k total,        0k used,  4087804k
free,   945336k
cached
 
-  PID USER      PR  NI  VIRT  RES  SHR S %CPU
%MEM    TIME+  COMMAND
- 3352 jacob     20   0  262m  644  428 S  286  0.0   0:17.16
spin
- 3341 root     -51   0     0    0    0 D   25  0.0   0:01.62
kidle_inject/0
- 3344 root     -51   0     0    0    0 D   25  0.0   0:01.60
kidle_inject/3
- 3342 root     -51   0     0    0    0 D   25  0.0   0:01.61
kidle_inject/1
- 3343 root     -51   0     0    0    0 D   25  0.0   0:01.60
kidle_inject/2
- 2935 jacob     20   0  696m 125m  35m S    5  3.3   0:31.11
firefox
- 1546 root      20   0  158m  20m 6640 S    3  0.5   0:26.97
Xorg
- 2100 jacob     20   0 1223m  88m  30m S    3  2.3   0:23.68
compiz
+    PID USER      PR  NI  VIRT  RES  SHR S %CPU
%MEM    TIME+  COMMAND
+   3352 jacob     20   0  262m  644  428 S  286  0.0   0:17.16
spin
+   3341 root     -51   0     0    0    0 D   25  0.0   0:01.62
kidle_inject/0
+   3344 root     -51   0     0    0    0 D   25  0.0   0:01.60
kidle_inject/3
+   3342 root     -51   0     0    0    0 D   25  0.0   0:01.61
kidle_inject/1
+   3343 root     -51   0     0    0    0 D   25  0.0   0:01.60
kidle_inject/2
+   2935 jacob     20   0  696m 125m  35m S    5  3.3   0:31.11
firefox
+   1546 root      20   0  158m  20m 6640 S    3  0.5   0:26.97
Xorg
+   2100 jacob     20   0 1223m  88m  30m S    3  2.3   0:23.68
compiz
 
 Tests have shown that by using the powerclamp driver as a
cooling
 device, a PID based userspace thermal controller can manage to
diff --git a/Documentation/thermal/nouveau_thermal
b/Documentation/thermal/nouveau_thermal.rst
similarity index 64%
rename from Documentation/thermal/nouveau_thermal
rename to Documentation/thermal/nouveau_thermal.rst
index 6e17a11efcb0..37255fd6735d 100644
--- a/Documentation/thermal/nouveau_thermal
+++ b/Documentation/thermal/nouveau_thermal.rst
@@ -1,13 +1,15 @@
+=====================
 Kernel driver nouveau
-===================
+=====================
 
 Supported chips:
+
 * NV43+
 
 Authors: Martin Peres (mupuf) [off-list ref]
 
 Description
----------
+-----------
 
 This driver allows to read the GPU core temperature, drive the
GPU
fan and
 set temperature alarms.
@@ -19,20 +21,25 @@ interface is likely not to work. This
document
may then not cover your situation
 entirely.
 
 Temperature management
---------------------
+----------------------
 
 Temperature is exposed under as a read-only HWMON attribute
temp1_input.
 
 In order to protect the GPU from overheating, Nouveau supports 4
configurable
 temperature thresholds:
 
- * Fan_boost: Fan speed is set to 100% when reaching this
temperature;
- * Downclock: The GPU will be downclocked to reduce its power
dissipation;
- * Critical: The GPU is put on hold to further lower power
dissipation;
- * Shutdown: Shut the computer down to protect your GPU.
+ * Fan_boost:
+	Fan speed is set to 100% when reaching this temperature;
+ * Downclock:
+	The GPU will be downclocked to reduce its power
dissipation;
+ * Critical:
+	The GPU is put on hold to further lower power
dissipation;
+ * Shutdown:
+	Shut the computer down to protect your GPU.
 
-WARNING: Some of these thresholds may not be used by Nouveau
depending
-on your chipset.
+WARNING:
+	Some of these thresholds may not be used by Nouveau
depending
+	on your chipset.
 
 The default value for these thresholds comes from the GPU's
vbios.
These
 thresholds can be configured thanks to the following HWMON
attributes:
@@ -46,19 +53,24 @@ NOTE: Remember that the values are stored as
milli degrees Celsius. Don't forget
 to multiply!
 
 Fan management
-------------
+--------------
 
 Not all cards have a drivable fan. If you do, then the following
HWMON
 attributes should be available:
 
- * pwm1_enable: Current fan management mode (NONE, MANUAL or
AUTO);
- * pwm1: Current PWM value (power percentage);
- * pwm1_min: The minimum PWM speed allowed;
- * pwm1_max: The maximum PWM speed allowed (bypassed when
hitting
Fan_boost);
+ * pwm1_enable:
+	Current fan management mode (NONE, MANUAL or AUTO);
+ * pwm1:
+	Current PWM value (power percentage);
+ * pwm1_min:
+	The minimum PWM speed allowed;
+ * pwm1_max:
+	The maximum PWM speed allowed (bypassed when hitting
Fan_boost);
 
 You may also have the following attribute:
 
- * fan1_input: Speed in RPM of your fan.
+ * fan1_input:
+	Speed in RPM of your fan.
 
 Your fan can be driven in different modes:
 
@@ -66,14 +78,16 @@ Your fan can be driven in different modes:
  * 1: The fan can be driven in manual (use pwm1 to change the
speed);
  * 2; The fan is driven automatically depending on the
temperature.
 
-NOTE: Be sure to use the manual mode if you want to drive the
fan
speed manually
+NOTE:
+  Be sure to use the manual mode if you want to drive the fan
speed
manually
 
-NOTE2: When operating in manual mode outside the vbios-defined
-[PWM_min, PWM_max] range, the reported fan speed (RPM) may not
be
accurate
-depending on your hardware.
+NOTE2:
+  When operating in manual mode outside the vbios-defined
+  [PWM_min, PWM_max] range, the reported fan speed (RPM) may not
be
accurate
+  depending on your hardware.
 
 Bug reports
----------
+-----------
 
 Thermal management on Nouveau is new and may not work on all
cards.
If you have
 inquiries, please ping mupuf on IRC (#nouveau, freenode).
diff --git a/Documentation/thermal/power_allocator.txt
b/Documentation/thermal/power_allocator.rst
similarity index 74%
rename from Documentation/thermal/power_allocator.txt
rename to Documentation/thermal/power_allocator.rst
index 9fb0ff06dca9..67b6a3297238 100644
--- a/Documentation/thermal/power_allocator.txt
+++ b/Documentation/thermal/power_allocator.rst
@@ -1,3 +1,4 @@
+=================================
 Power allocator governor tunables
 =================================
 
@@ -25,36 +26,36 @@ temperature as the control input and power as
the
controlled output:
     P_max = k_p * e + k_i * err_integral + k_d * diff_err +
sustainable_power
 
 where
-    e = desired_temperature - current_temperature
-    err_integral is the sum of previous errors
-    diff_err = e - previous_error
+   -  e = desired_temperature - current_temperature
+   -  err_integral is the sum of previous errors
+   -  diff_err = e - previous_error
 
-It is similar to the one depicted below:
+It is similar to the one depicted below::
 
-                                      k_d
-                                       |
-current_temp                           |
-     |                                 v
-     |                +----------+   +---+
-     |         +----->| diff_err |-->| X |------+
-     |         |      +----------+   +---+      |
-     |         |                                |      tdp      
  ac
tor
-     |         |                      k_i       |       |  get_r
eque
sted_power()
-     |         |                       |        |       |       
 |  
   |
-     |         |                       |        |       |       
 |  
   | ...
-     v         |                       v        v       v       
 v  
   v
-   +---+       |      +-------+      +---+    +---+   +---+   +-
----
-----+
-   | S |-------+----->| sum e |----->| X |--->| S |-->| S |  
-->|power     |  
-   +---+       |      +-------+      +---+    +---+   +---
+   |allocation|
-     ^         |                                ^             +-
----
-----+
-     |         |                                |               
 |  
   |
-     |         |        +---
+                   |                |     |
-     |         +------->| X |-------------------
+                v     v
-     |                  +---
+                               granted
performance
-desired_temperature       ^
-                          |
-                          |
-                      k_po/k_pu
+				      k_d
+				       |
+  current_temp                         |
+       |                               v
+       |              +----------+   +---+
+       |       +----->| diff_err |-->| X |------+
+       |       |      +----------+   +---+      |
+       |       |                                |      tdp      
  ac
tor
+       |       |                      k_i       |       |  get_r
eque
sted_power()
+       |       |                       |        |       |       
 |  
   |
+       |       |                       |        |       |       
 |  
   | ...
+       v       |                       v        v       v       
 v  
   v
+     +---+     |      +-------+      +---+    +---+   +---+   +-
----
-----+
+     | S |-----+----->| sum e |----->| X |--->| S |-->| S |  
-->|power     |  
+     +---+     |      +-------+      +---+    +---+   +---
+   |allocation|
+       ^       |                                ^             +-
----
-----+
+       |       |                                |               
 |  
   |
+       |       |        +---
+                   |                |     |
+       |       +------->| X |-------------------
+                v     v
+       |                +---
+                               granted
performance
+  desired_temperature     ^
+			  |
+			  |
+		      k_po/k_pu
 
 Sustainable power
 -----------------
@@ -73,7 +74,7 @@ is typically 2000mW, while on a 10" tablet is
around 4500mW (may vary
 depending on screen size).
 
 If you are using device tree, do add it as a property of the
-thermal-zone.  For example:
+thermal-zone.  For example::
 
 	thermal-zones {
 		soc_thermal {
@@ -85,7 +86,7 @@ thermal-zone.  For example:
 Instead, if the thermal zone is registered from the platform
code,
pass a
 `thermal_zone_params` that has a `sustainable_power`.  If no
 `thermal_zone_params` were being passed, then something like
below
-will suffice:
+will suffice::
 
 	static const struct thermal_zone_params tz_params = {
 		.sustainable_power = 3500,
@@ -112,18 +113,18 @@ available capacity at a low
temperature.  On
the other hand, a high
 value of `k_pu` will result in the governor granting very high
power
 while temperature is low, and may lead to temperature
overshooting.
 
-The default value for `k_pu` is:
+The default value for `k_pu` is::
 
     2 * sustainable_power / (desired_temperature -
switch_on_temp)
 
 This means that at `switch_on_temp` the output of the
controller's
 proportional term will be 2 * `sustainable_power`.  The default
value
-for `k_po` is:
+for `k_po` is::
 
     sustainable_power / (desired_temperature - switch_on_temp)
 
 Focusing on the proportional and feed forward values of the PID
-controller equation we have:
+controller equation we have::
 
     P_max = k_p * e + sustainable_power
 
@@ -134,21 +135,23 @@ is the desired one, then the proportional
component is zero and
 thermal equilibrium under constant load.  `sustainable_power` is
only
 an estimate, which is the reason for closed-loop control such as
this.
 
-Expanding `k_pu` we get:
+Expanding `k_pu` we get::
+
     P_max = 2 * sustainable_power * (T_set - T) / (T_set - T_on)
+
-        sustainable_power
+	sustainable_power
 
-where
-    T_set is the desired temperature
-    T is the current temperature
-    T_on is the switch on temperature
+where:
+
+    - T_set is the desired temperature
+    - T is the current temperature
+    - T_on is the switch on temperature
 
 When the current temperature is the switch_on temperature, the
above
-formula becomes:
+formula becomes::
 
     P_max = 2 * sustainable_power * (T_set - T_on) / (T_set -
T_on)
+
-        sustainable_power = 2 * sustainable_power +
sustainable_power =
-        3 * sustainable_power
+	sustainable_power = 2 * sustainable_power +
sustainable_power =
+	3 * sustainable_power
 
 Therefore, the proportional term alone linearly decreases power
from
 3 * `sustainable_power` to `sustainable_power` as the
temperature
@@ -178,11 +181,18 @@ Cooling device power API
 Cooling devices controlled by this governor must supply the
additional
 "power" API in their `cooling_device_ops`.  It consists on three
ops:
 
-1. int get_requested_power(struct thermal_cooling_device *cdev,
-	struct thermal_zone_device *tz, u32 *power);
-@cdev: The `struct thermal_cooling_device` pointer
-@tz: thermal zone in which we are currently operating
-@power: pointer in which to store the calculated power
+1. ::
+
+    int get_requested_power(struct thermal_cooling_device *cdev,
+			    struct thermal_zone_device *tz, u32
*power);
+
+
+@cdev:
+	The `struct thermal_cooling_device` pointer
+@tz:
+	thermal zone in which we are currently operating
+@power:
+	pointer in which to store the calculated power
 
 `get_requested_power()` calculates the power requested by the
device
 in milliwatts and stores it in @power .  It should return 0 on
@@ -190,23 +200,37 @@ success, -E* on failure.  This is currently
used by the power
 allocator governor to calculate how much power to give to each
cooling
 device.
 
-2. int state2power(struct thermal_cooling_device *cdev, struct
-        thermal_zone_device *tz, unsigned long state, u32
*power);
-@cdev: The `struct thermal_cooling_device` pointer
-@tz: thermal zone in which we are currently operating
-@state: A cooling device state
-@power: pointer in which to store the equivalent power
+2. ::
+
+	int state2power(struct thermal_cooling_device *cdev,
struct
+			thermal_zone_device *tz, unsigned long
state,
+			u32 *power);
+
+@cdev:
+	The `struct thermal_cooling_device` pointer
+@tz:
+	thermal zone in which we are currently operating
+@state:
+	A cooling device state
+@power:
+	pointer in which to store the equivalent power
 
 Convert cooling device state @state into power consumption in
 milliwatts and store it in @power.  It should return 0 on
success,
-E*
 on failure.  This is currently used by thermal core to calculate
the
 maximum power that an actor can consume.
 
-3. int power2state(struct thermal_cooling_device *cdev, u32
power,
-	unsigned long *state);
-@cdev: The `struct thermal_cooling_device` pointer
-@power: power in milliwatts
-@state: pointer in which to store the resulting state
+3. ::
+
+	int power2state(struct thermal_cooling_device *cdev, u32
power,
+			unsigned long *state);
+
+@cdev:
+	The `struct thermal_cooling_device` pointer
+@power:
+	power in milliwatts
+@state:
+	pointer in which to store the resulting state
 
 Calculate a cooling device state that would make the device
consume
at
 most @power mW and store it in @state.  It should return 0 on
success,
diff --git a/Documentation/thermal/sysfs-api.txt
b/Documentation/thermal/sysfs-api.rst
similarity index 66%
rename from Documentation/thermal/sysfs-api.txt
rename to Documentation/thermal/sysfs-api.rst
index c3fa500df92c..e4930761d3e5 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.rst
@@ -1,3 +1,4 @@
+===================================
 Generic Thermal Sysfs driver How To
 ===================================
 
@@ -9,6 +10,7 @@ Copyright (c)  2008 Intel Corporation
 
 
 0. Introduction
+===============
 
 The generic thermal sysfs provides a set of interfaces for
thermal
zone
 devices (sensors) and thermal cooling devices (fan,
processor...) to
register
@@ -25,59 +27,90 @@ An intelligent thermal management application
can
make decisions based on
 inputs from thermal zone attributes (the current temperature and
trip point
 temperature) and throttle appropriate devices.
 
-[0-*]	denotes any positive number starting from 0
-[1-*]	denotes any positive number starting from 1
+- `[0-*]`	denotes any positive number starting from 0
+- `[1-*]`	denotes any positive number starting from 1
 
 1. thermal sysfs driver interface functions
+===========================================
 
 1.1 thermal zone device interface
-1.1.1 struct thermal_zone_device
*thermal_zone_device_register(char
*type,
-		int trips, int mask, void *devdata,
-		struct thermal_zone_device_ops *ops,
-		const struct thermal_zone_params *tzp,
-		int passive_delay, int polling_delay))
+---------------------------------
+
+    ::
+
+	struct thermal_zone_device
+	*thermal_zone_device_register(char *type,
+				      int trips, int mask, void
*devdata,
+				      struct
thermal_zone_device_ops
*ops,
+				      const struct
thermal_zone_params *tzp,
+				      int passive_delay, int
polling_delay))
 
     This interface function adds a new thermal zone device
(sensor)
to
-    /sys/class/thermal folder as thermal_zone[0-*]. It tries to
bind
all the
+    /sys/class/thermal folder as `thermal_zone[0-*]`. It tries
to
bind all the
     thermal cooling devices registered at the same time.
 
-    type: the thermal zone type.
-    trips: the total number of trip points this thermal zone
supports.
-    mask: Bit string: If 'n'th bit is set, then trip point 'n'
is
writeable.
-    devdata: device private data
-    ops: thermal zone device call-backs.
-	.bind: bind the thermal zone device with a thermal
cooling
device.
-	.unbind: unbind the thermal zone device with a thermal
cooling device.
-	.get_temp: get the current temperature of the thermal
zone.
-	.set_trips: set the trip points window. Whenever the
current
temperature
+    type:
+	the thermal zone type.
+    trips:
+	the total number of trip points this thermal zone
supports.
+    mask:
+	Bit string: If 'n'th bit is set, then trip point 'n' is
writeable.
+    devdata:
+	device private data
+    ops:
+	thermal zone device call-backs.
+
+	.bind:
+		bind the thermal zone device with a thermal
cooling
device.
+	.unbind:
+		unbind the thermal zone device with a thermal
cooling device.
+	.get_temp:
+		get the current temperature of the thermal zone.
+	.set_trips:
+		    set the trip points window. Whenever the
current
temperature
 		    is updated, the trip points immediately
below
and above the
 		    current temperature are found.
-	.get_mode: get the current mode (enabled/disabled) of
the
thermal zone.
-	    - "enabled" means the kernel thermal management is
enabled.
-	    - "disabled" will prevent kernel thermal driver
action
upon trip points
-	      so that user applications can take charge of
thermal
management.
-	.set_mode: set the mode (enabled/disabled) of the
thermal
zone.
-	.get_trip_type: get the type of certain trip point.
-	.get_trip_temp: get the temperature above which the
certain
trip point
+	.get_mode:
+		   get the current mode (enabled/disabled) of
the
thermal zone.
+
+			- "enabled" means the kernel thermal
management is
+			  enabled.
+			- "disabled" will prevent kernel thermal
driver action
+			  upon trip points so that user
applications
can take
+			  charge of thermal management.
+	.set_mode:
+		set the mode (enabled/disabled) of the thermal
zone.
+	.get_trip_type:
+		get the type of certain trip point.
+	.get_trip_temp:
+			get the temperature above which the
certain
trip point
 			will be fired.
-	.set_emul_temp: set the emulation temperature which
helps in
debugging
+	.set_emul_temp:
+			set the emulation temperature which
helps in
debugging
 			different threshold temperature points.
-    tzp: thermal zone platform parameters.
-    passive_delay: number of milliseconds to wait between polls
when
+    tzp:
+	thermal zone platform parameters.
+    passive_delay:
+	number of milliseconds to wait between polls when
 	performing passive cooling.
-    polling_delay: number of milliseconds to wait between polls
when
checking
+    polling_delay:
+	number of milliseconds to wait between polls when
checking
 	whether trip points have been crossed (0 for interrupt
driven systems).
 
+    ::
 
-1.1.2 void thermal_zone_device_unregister(struct
thermal_zone_device
*tz)
+	void thermal_zone_device_unregister(struct
thermal_zone_device *tz)
 
     This interface function removes the thermal zone device.
     It deletes the corresponding entry from /sys/class/thermal
folder and
     unbinds all the thermal cooling devices it uses.
 
-1.1.3 struct thermal_zone_device
*thermal_zone_of_sensor_register(
-		struct device *dev, int sensor_id, void *data,
-		const struct thermal_zone_of_device_ops *ops)
+	::
+
+	   struct thermal_zone_device
+	   *thermal_zone_of_sensor_register(struct device *dev,
int
sensor_id,
+				void *data,
+				const struct
thermal_zone_of_device_ops *ops)
 
 	This interface adds a new sensor to a DT thermal zone.
 	This function will search the list of thermal zones
described in
@@ -87,25 +120,33 @@ temperature) and throttle appropriate
devices.
 	thermal zone device.
 
 	The parameters for this interface are:
-	dev:		Device node of sensor containing
valid
node pointer in
+
+	dev:
+			Device node of sensor containing valid
node
pointer in
 			dev->of_node.
-	sensor_id:	a sensor identifier, in case the
sensor IP
has more
+	sensor_id:
+			a sensor identifier, in case the sensor
IP
has more
 			than one sensors
-	data:		a private pointer (owned by the
caller)
that will be
+	data:
+			a private pointer (owned by the caller)
that
will be
 			passed back, when a temperature reading
is
needed.
-	ops:		struct thermal_zone_of_device_ops *.
+	ops:
+			`struct thermal_zone_of_device_ops *`.
 
-			get_temp:	a pointer to a function
that reads the
+			==============  ========================
====
===========
+			get_temp	a pointer to a function
that
reads the
 					sensor temperature. This
is
mandatory
 					callback provided by
sensor
driver.
-			set_trips:      a pointer to a function
that
sets a
+			set_trips	a pointer to a function
that sets a
 					temperature window. When
this window is
 					left the driver must
inform
the thermal
 					core via
thermal_zone_device_update.
-			get_trend: 	a pointer to a
function
that reads the
+			get_trend 	a pointer to a
function
that reads the
 					sensor temperature
trend.
-			set_emul_temp:	a pointer to a
function that sets
+			set_emul_temp	a pointer to a
function
that sets
 					sensor emulated
temperature.
+			==============  ========================
====
===========
+
 	The thermal zone temperature is provided by the
get_temp()
function
 	pointer of thermal_zone_of_device_ops. When called, it
will
 	have the private pointer @data back.
@@ -114,8 +155,10 @@ temperature) and throttle appropriate
devices.
 	handle. Caller should check the return handle with
IS_ERR()
for finding
 	whether success or not.
 
-1.1.4 void thermal_zone_of_sensor_unregister(struct device *dev,
-		struct thermal_zone_device *tzd)
+	::
+
+	    void thermal_zone_of_sensor_unregister(struct device
*dev,
+						   struct
thermal_zone_device *tzd)
 
 	This interface unregisters a sensor from a DT thermal
zone
which was
 	successfully added by interface
thermal_zone_of_sensor_register().
@@ -124,21 +167,29 @@ temperature) and throttle appropriate
devices.
 	interface. It will also silent the zone by remove the
.get_temp() and
 	get_trend() thermal zone device callbacks.
 
-1.1.5 struct thermal_zone_device
*devm_thermal_zone_of_sensor_register(
-		struct device *dev, int sensor_id,
-		void *data, const struct
thermal_zone_of_device_ops
*ops)
+	::
+
+	  struct thermal_zone_device
+	  *devm_thermal_zone_of_sensor_register(struct device
*dev,
+				int sensor_id,
+				void *data,
+				const struct
thermal_zone_of_device_ops *ops)
 
 	This interface is resource managed version of
 	thermal_zone_of_sensor_register().
+
 	All details of thermal_zone_of_sensor_register()
described
in
 	section 1.1.3 is applicable here.
+
 	The benefit of using this interface to register sensor
is
that it
 	is not require to explicitly call
thermal_zone_of_sensor_unregister()
 	in error path or during driver unbinding as this is done
by
driver
 	resource manager.
 
-1.1.6 void devm_thermal_zone_of_sensor_unregister(struct device
*dev,
-		struct thermal_zone_device *tzd)
+	::
+
+		void
devm_thermal_zone_of_sensor_unregister(struct
device *dev,
+						struct
thermal_zone_device *tzd)
 
 	This interface is resource managed version of
 	thermal_zone_of_sensor_unregister().
@@ -147,123 +198,186 @@ temperature) and throttle appropriate
devices.
 	Normally this function will not need to be called and
the
resource
 	management code will ensure that the resource is freed.
 
-1.1.7 int thermal_zone_get_slope(struct thermal_zone_device *tz)
+	::
+
+		int thermal_zone_get_slope(struct
thermal_zone_device *tz)
 
 	This interface is used to read the slope attribute value
 	for the thermal zone device, which might be useful for
platform
 	drivers for temperature calculations.
 
-1.1.8 int thermal_zone_get_offset(struct thermal_zone_device
*tz)
+	::
+
+		int thermal_zone_get_offset(struct
thermal_zone_device *tz)
 
 	This interface is used to read the offset attribute
value
 	for the thermal zone device, which might be useful for
platform
 	drivers for temperature calculations.
 
 1.2 thermal cooling device interface
-1.2.1 struct thermal_cooling_device
*thermal_cooling_device_register(char *name,
-		void *devdata, struct thermal_cooling_device_ops
*)
+------------------------------------
+
+
+    ::
+
+	struct thermal_cooling_device
+	*thermal_cooling_device_register(char *name,
+			void *devdata, struct
thermal_cooling_device_ops *)
 
     This interface function adds a new thermal cooling device
(fan/processor/...)
-    to /sys/class/thermal/ folder as cooling_device[0-*]. It
tries
to bind itself
+    to /sys/class/thermal/ folder as `cooling_device[0-*]`. It
tries
to bind itself
     to all the thermal zone devices registered at the same time.
-    name: the cooling device name.
-    devdata: device private data.
-    ops: thermal cooling devices call-backs.
-	.get_max_state: get the Maximum throttle state of the
cooling device.
-	.get_cur_state: get the Currently requested throttle
state
of the cooling device.
-	.set_cur_state: set the Current throttle state of the
cooling device.
-
-1.2.2 void thermal_cooling_device_unregister(struct
thermal_cooling_device *cdev)
+
+    name:
+	the cooling device name.
+    devdata:
+	device private data.
+    ops:
+	thermal cooling devices call-backs.
+
+	.get_max_state:
+		get the Maximum throttle state of the cooling
device.
+	.get_cur_state:
+		get the Currently requested throttle state of
the
+		cooling device.
+	.set_cur_state:
+		set the Current throttle state of the cooling
device.
+
+    ::
+
+	void thermal_cooling_device_unregister(struct
thermal_cooling_device *cdev)
 
     This interface function removes the thermal cooling device.
     It deletes the corresponding entry from /sys/class/thermal
folder and
     unbinds itself from all the thermal zone devices using it.
 
 1.3 interface for binding a thermal zone device with a thermal
cooling device
-1.3.1 int thermal_zone_bind_cooling_device(struct
thermal_zone_device *tz,
-	int trip, struct thermal_cooling_device *cdev,
-	unsigned long upper, unsigned long lower, unsigned int
weight);
+--------------------------------------------------------------
----
-----------
+
+    ::
+
+	int thermal_zone_bind_cooling_device(struct
thermal_zone_device *tz,
+		int trip, struct thermal_cooling_device *cdev,
+		unsigned long upper, unsigned long lower,
unsigned
int weight);
 
     This interface function binds a thermal cooling device to a
particular trip
     point of a thermal zone device.
+
     This function is usually called in the thermal zone device
.bind
callback.
-    tz: the thermal zone device
-    cdev: thermal cooling device
-    trip: indicates which trip point in this thermal zone the
cooling device
-          is associated with.
-    upper:the Maximum cooling state for this trip point.
-          THERMAL_NO_LIMIT means no upper limit,
+
+    tz:
+	  the thermal zone device
+    cdev:
+	  thermal cooling device
+    trip:
+	  indicates which trip point in this thermal zone the
cooling device
+	  is associated with.
+    upper:
+	  the Maximum cooling state for this trip point.
+	  THERMAL_NO_LIMIT means no upper limit,
 	  and the cooling device can be in max_state.
-    lower:the Minimum cooling state can be used for this trip
point.
-          THERMAL_NO_LIMIT means no lower limit,
+    lower:
+	  the Minimum cooling state can be used for this trip
point.
+	  THERMAL_NO_LIMIT means no lower limit,
 	  and the cooling device can be in cooling state 0.
-    weight: the influence of this cooling device in this thermal
-            zone.  See 1.4.1 below for more information.
+    weight:
+	  the influence of this cooling device in this thermal
+	  zone.  See 1.4.1 below for more information.
 
-1.3.2 int thermal_zone_unbind_cooling_device(struct
thermal_zone_device *tz,
-		int trip, struct thermal_cooling_device *cdev);
+    ::
+
+	int thermal_zone_unbind_cooling_device(struct
thermal_zone_device *tz,
+				int trip, struct
thermal_cooling_device *cdev);
 
     This interface function unbinds a thermal cooling device
from a
particular
     trip point of a thermal zone device. This function is
usually
called in
     the thermal zone device .unbind callback.
-    tz: the thermal zone device
-    cdev: thermal cooling device
-    trip: indicates which trip point in this thermal zone the
cooling device
-          is associated with.
+
+    tz:
+	the thermal zone device
+    cdev:
+	thermal cooling device
+    trip:
+	indicates which trip point in this thermal zone the
cooling
device
+	is associated with.
 
 1.4 Thermal Zone Parameters
-1.4.1 struct thermal_bind_params
+---------------------------
+
+    ::
+
+	struct thermal_bind_params
+
     This structure defines the following parameters that are
used to
bind
     a zone with a cooling device for a particular trip point.
-    .cdev: The cooling device pointer
-    .weight: The 'influence' of a particular cooling device on
this
-             zone. This is relative to the rest of the cooling
-             devices. For example, if all cooling devices have a
-             weight of 1, then they all contribute the same. You
can
-             use percentages if you want, but it's not
mandatory. A
-             weight of 0 means that this cooling device doesn't
-             contribute to the cooling of this zone unless all
cooling
-             devices have a weight of 0. If all weights are 0,
then
-             they all contribute the same.
-    .trip_mask:This is a bit mask that gives the binding
relation
between
-               this thermal zone and cdev, for a particular trip
point.
-               If nth bit is set, then the cdev and thermal zone
are
bound
-               for trip point n.
-    .binding_limits: This is an array of cooling state limits.
Must
have
-                     exactly 2 *
thermal_zone.number_of_trip_points.
It is an
-                     array consisting of tuples <lower-state
upper-  
state> of  
-                     state limits. Each trip will be associated
with
one state
-                     limit tuple when binding. A NULL pointer
means
-                     <THERMAL_NO_LIMITS THERMAL_NO_LIMITS> on
all
trips.
-                     These limits are used when binding a cdev
to a
trip point.
-    .match: This call back returns success(0) if the 'tz and
cdev'
need to
+
+    .cdev:
+	     The cooling device pointer
+    .weight:
+	     The 'influence' of a particular cooling device on
this
+	     zone. This is relative to the rest of the cooling
+	     devices. For example, if all cooling devices have a
+	     weight of 1, then they all contribute the same. You
can
+	     use percentages if you want, but it's not
mandatory. A
+	     weight of 0 means that this cooling device doesn't
+	     contribute to the cooling of this zone unless all
cooling
+	     devices have a weight of 0. If all weights are 0,
then
+	     they all contribute the same.
+    .trip_mask:
+	       This is a bit mask that gives the binding
relation
between
+	       this thermal zone and cdev, for a particular trip
point.
+	       If nth bit is set, then the cdev and thermal zone
are
bound
+	       for trip point n.
+    .binding_limits:
+		     This is an array of cooling state limits.
Must
have
+		     exactly 2 *
thermal_zone.number_of_trip_points.
It is an
+		     array consisting of tuples <lower-state
upper-  
state> of  
+		     state limits. Each trip will be associated
with
one state
+		     limit tuple when binding. A NULL pointer
means
+		     <THERMAL_NO_LIMITS THERMAL_NO_LIMITS> on
all
trips.
+		     These limits are used when binding a cdev
to a
trip point.
+    .match:
+	    This call back returns success(0) if the 'tz and
cdev'
need to
 	    be bound, as per platform data.
-1.4.2 struct thermal_zone_params
+
+    ::
+
+	struct thermal_zone_params
+
     This structure defines the platform level parameters for a
thermal zone.
     This data, for each thermal zone should come from the
platform
layer.
     This is an optional feature where some platforms can choose
not
to
     provide this data.
-    .governor_name: Name of the thermal governor used for this
zone
-    .no_hwmon: a boolean to indicate if the thermal to hwmon
sysfs
interface
-               is required. when no_hwmon == false, a hwmon
sysfs
interface
-               will be created. when no_hwmon == true, nothing
will
be done.
-               In case the thermal_zone_params is NULL, the
hwmon
interface
-               will be created (for backward compatibility).
-    .num_tbps: Number of thermal_bind_params entries for this
zone
-    .tbp: thermal_bind_params entries
+
+    .governor_name:
+	       Name of the thermal governor used for this zone
+    .no_hwmon:
+	       a boolean to indicate if the thermal to hwmon
sysfs
interface
+	       is required. when no_hwmon == false, a hwmon
sysfs
interface
+	       will be created. when no_hwmon == true, nothing
will
be done.
+	       In case the thermal_zone_params is NULL, the
hwmon
interface
+	       will be created (for backward compatibility).
+    .num_tbps:
+	       Number of thermal_bind_params entries for this
zone
+    .tbp:
+	       thermal_bind_params entries
 
 2. sysfs attributes structure
+=============================
 
+==	================
 RO	read only value
 WO	write only value
 RW	read/write value
+==	================
 
 Thermal sysfs attributes will be represented under
/sys/class/thermal.
 Hwmon sysfs I/F extension is also available under
/sys/class/hwmon
 if hwmon is compiled in or built as a module.
 
-Thermal zone device sys I/F, created once it's registered:
-/sys/class/thermal/thermal_zone[0-*]:
+Thermal zone device sys I/F, created once it's registered::
+
+  /sys/class/thermal/thermal_zone[0-*]:
     |---type:			Type of the thermal zone
     |---temp:			Current temperature
     |---mode:			Working mode of the thermal
zone
@@ -282,8 +396,9 @@ Thermal zone device sys I/F, created once
it's
registered:
     |---slope:                  Slope constant applied as linear
extrapolation
     |---offset:                 Offset constant applied as
linear
extrapolation
 
-Thermal cooling device sys I/F, created once it's registered:
-/sys/class/thermal/cooling_device[0-*]:
+Thermal cooling device sys I/F, created once it's registered::
+
+  /sys/class/thermal/cooling_device[0-*]:
     |---type:			Type of the cooling
device(processor/fan/...)
     |---max_state:		Maximum cooling state of the
cooling device
     |---cur_state:		Current cooling state of the
cooling device
@@ -299,11 +414,13 @@ the relationship between a thermal zone and
its
associated cooling device.
 They are created/removed for each successful execution of
 thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_dev
ice.
 
-/sys/class/thermal/thermal_zone[0-*]:
+::
+
+  /sys/class/thermal/thermal_zone[0-*]:
     |---cdev[0-*]:		[0-*]th cooling device in
current
thermal zone
     |---cdev[0-*]_trip_point:	Trip point that cdev[0-*]
is
associated with
     |---cdev[0-*]_weight:       Influence of the cooling device
in
-                                this thermal zone
+				this thermal zone
 
 Besides the thermal zone device sysfs I/F and cooling device
sysfs
I/F,
 the generic thermal driver also creates a hwmon sysfs I/F for
each
_type_
@@ -311,16 +428,17 @@ of thermal zone device. E.g. the generic
thermal driver registers one hwmon
 class device and build the associated hwmon sysfs I/F for all
the
registered
 ACPI thermal zones.
 
-/sys/class/hwmon/hwmon[0-*]:
+::
+
+  /sys/class/hwmon/hwmon[0-*]:
     |---name:			The type of the thermal
zone
devices
     |---temp[1-*]_input:	The current temperature of
thermal
zone [1-*]
     |---temp[1-*]_critical:	The critical trip point of
thermal zone [1-*]
 
 Please read Documentation/hwmon/sysfs-interface.rst for
additional
information.
 
-***************************
-* Thermal zone attributes *
-***************************
+Thermal zone attributes
+-----------------------
 
 type
 	Strings which represent the thermal zone type.
@@ -340,54 +458,67 @@ mode
 	This file gives information about the algorithm that is
currently
 	managing the thermal zone. It can be either default
kernel
based
 	algorithm or user space application.
-	enabled		= enable Kernel Thermal
management.
-	disabled	= Preventing kernel thermal zone driver
actions upon
+
+	enabled
+			  enable Kernel Thermal management.
+	disabled
+			  Preventing kernel thermal zone driver
actions upon
 			  trip points so that user application
can
take full
 			  charge of the thermal management.
+
 	RW, Optional
 
 policy
 	One of the various thermal governors used for a
particular
zone.
+
 	RW, Required
 
 available_policies
 	Available thermal governors which can be used for a
particular zone.
+
 	RO, Required
 
-trip_point_[0-*]_temp
+`trip_point_[0-*]_temp`
 	The temperature above which trip point will be fired.
+
 	Unit: millidegree Celsius
+
 	RO, Optional
 
-trip_point_[0-*]_type
+`trip_point_[0-*]_type`
 	Strings which indicate the type of the trip point.
-	E.g. it can be one of critical, hot, passive, active[0-
*]
for ACPI
+
+	E.g. it can be one of critical, hot, passive, `active[0-
*]`
for ACPI
 	thermal zone.
+
 	RO, Optional
 
-trip_point_[0-*]_hyst
+`trip_point_[0-*]_hyst`
 	The hysteresis value for a trip point, represented as an
integer
 	Unit: Celsius
 	RW, Optional
 
-cdev[0-*]
+`cdev[0-*]`
 	Sysfs link to the thermal cooling device node where the
sys
I/F
 	for cooling device throttling control represents.
+
 	RO, Optional
 
-cdev[0-*]_trip_point
-	The trip point in this thermal zone which cdev[0-*] is
associated
+`cdev[0-*]_trip_point`
+	The trip point in this thermal zone which `cdev[0-*]` is
associated
 	with; -1 means the cooling device is not associated with
any
trip
 	point.
+
 	RO, Optional
 
-cdev[0-*]_weight
-        The influence of cdev[0-*] in this thermal zone. This
value
-        is relative to the rest of cooling devices in the
thermal
-        zone. For example, if a cooling device has a weight
double
-        than that of other, it's twice as effective in cooling
the
-        thermal zone.
-        RW, Optional
+`cdev[0-*]_weight`
+	The influence of `cdev[0-*]` in this thermal zone. This
value
+	is relative to the rest of cooling devices in the
thermal
+	zone. For example, if a cooling device has a weight
double
+	than that of other, it's twice as effective in cooling
the
+	thermal zone.
+
+	RW, Optional
 
 passive
 	Attribute is only present for zones in which the passive
cooling
@@ -395,8 +526,11 @@ passive
 	and can be set to a temperature (in millidegrees) to
enable
a
 	passive trip point for the zone. Activation is done by
polling with
 	an interval of 1 second.
+
 	Unit: millidegrees Celsius
+
 	Valid values: 0 (disabled) or greater than 1000
+
 	RW, Optional
 
 emul_temp
@@ -407,17 +541,21 @@ emul_temp
 	threshold and its associated cooling action. This is
write
only node
 	and writing 0 on this node should disable emulation.
 	Unit: millidegree Celsius
+
 	WO, Optional
 
-	  WARNING: Be careful while enabling this option on
production systems,
-	  because userland can easily disable the thermal policy
by
simply
-	  flooding this sysfs node with low temperature values.
+	  WARNING:
+	    Be careful while enabling this option on production
systems,
+	    because userland can easily disable the thermal
policy
by simply
+	    flooding this sysfs node with low temperature
values.
 
 sustainable_power
 	An estimate of the sustained power that can be
dissipated by
 	the thermal zone. Used by the power allocator governor.
For
-	more information see
Documentation/thermal/power_allocator.txt
+	more information see
Documentation/thermal/power_allocator.rst
+
 	Unit: milliwatts
+
 	RW, Optional
 
 k_po
@@ -425,7 +563,8 @@ k_po
 	controller during temperature overshoot. Temperature
overshoot
 	is when the current temperature is above the "desired
 	temperature" trip point. For more information see
-	Documentation/thermal/power_allocator.txt
+	Documentation/thermal/power_allocator.rst
+
 	RW, Optional
 
 k_pu
@@ -433,20 +572,23 @@ k_pu
 	controller during temperature undershoot. Temperature
undershoot
 	is when the current temperature is below the "desired
 	temperature" trip point. For more information see
-	Documentation/thermal/power_allocator.txt
+	Documentation/thermal/power_allocator.rst
+
 	RW, Optional
 
 k_i
 	The integral term of the power allocator governor's PID
 	controller. This term allows the PID controller to
compensate
 	for long term drift. For more information see
-	Documentation/thermal/power_allocator.txt
+	Documentation/thermal/power_allocator.rst
+
 	RW, Optional
 
 k_d
 	The derivative term of the power allocator governor's
PID
 	controller. For more information see
-	Documentation/thermal/power_allocator.txt
+	Documentation/thermal/power_allocator.rst
+
 	RW, Optional
 
 integral_cutoff
@@ -456,8 +598,10 @@ integral_cutoff
 	example, if integral_cutoff is 0, then the integral term
only
 	accumulates error when temperature is above the desired
 	temperature trip point. For more information see
-	Documentation/thermal/power_allocator.txt
+	Documentation/thermal/power_allocator.rst
+
 	Unit: millidegree Celsius
+
 	RW, Optional
 
 slope
@@ -465,6 +609,7 @@ slope
 	to determine a hotspot temperature based off the
sensor's
 	raw readings. It is up to the device driver to determine
 	the usage of these values.
+
 	RW, Optional
 
 offset
@@ -472,28 +617,33 @@ offset
 	to determine a hotspot temperature based off the
sensor's
 	raw readings. It is up to the device driver to determine
 	the usage of these values.
+
 	RW, Optional
 
-*****************************
-* Cooling device attributes *
-*****************************
+Cooling device attributes
+-------------------------
 
 type
 	String which represents the type of device, e.g:
+
 	- for generic ACPI: should be "Fan", "Processor" or
"LCD"
 	- for memory controller device on intel_menlow platform:
 	  should be "Memory controller".
+
 	RO, Required
 
 max_state
 	The maximum permissible cooling state of this cooling
device.
+
 	RO, Required
 
 cur_state
 	The current cooling state of this cooling device.
 	The value can any integer numbers between 0 and
max_state:
+
 	- cur_state == 0 means no cooling
 	- cur_state == max_state means the maximum cooling.
+
 	RW, Required
 
 stats/reset
@@ -508,9 +658,11 @@ stats/time_in_state_ms:
 	units here is 10mS (similar to other time exported in
/proc).
 	RO, Required
 
+
 stats/total_trans:
 	A single positive value showing the total number of
times
the state of a
 	cooling device is changed.
+
 	RO, Required
 
 stats/trans_table:
@@ -522,6 +674,7 @@ stats/trans_table:
 	RO, Required
 
 3. A simple implementation
+==========================
 
 ACPI thermal zone may support multiple trip points like
critical,
hot,
 passive, active. If an ACPI thermal zone supports critical,
passive,
@@ -532,11 +685,10 @@ thermal_cooling_device. Both are considered
to
have the same
 effectiveness in cooling the thermal zone.
 
 If the processor is listed in _PSL method, and the fan is listed
in
_AL0
-method, the sys I/F structure will be built like this:
+method, the sys I/F structure will be built like this::
 
-/sys/class/thermal:
-
-|thermal_zone1:
+ /sys/class/thermal:
+  |thermal_zone1:
     |---type:			acpitz
     |---temp:			37000
     |---mode:			enabled
@@ -557,24 +709,24 @@ method, the sys I/F structure will be built
like this:
     |---cdev1_trip_point:	2	/* cdev1 can be used
for
active[0]*/
     |---cdev1_weight:           1024
 
-|cooling_device0:
+  |cooling_device0:
     |---type:			Processor
     |---max_state:		8
     |---cur_state:		0
 
-|cooling_device3:
+  |cooling_device3:
     |---type:			Fan
     |---max_state:		2
     |---cur_state:		0
 
-/sys/class/hwmon:
-
-|hwmon0:
+ /sys/class/hwmon:
+  |hwmon0:
     |---name:			acpitz
     |---temp1_input:		37000
     |---temp1_crit:		100000
 
 4. Event Notification
+=====================
 
 The framework includes a simple notification mechanism, in the
form
of a
 netlink event. Netlink socket initialization is done during the
_init_
@@ -587,21 +739,28 @@ event will be one of:{THERMAL_AUX0,
THERMAL_AUX1, THERMAL_CRITICAL,
 THERMAL_DEV_FAULT}. Notification can be sent when the current
temperature
 crosses any of the configured thresholds.
 
-5. Export Symbol APIs:
+5. Export Symbol APIs
+=====================
+
+5.1. get_tz_trend
+-----------------
 
-5.1: get_tz_trend:
 This function returns the trend of a thermal zone, i.e the rate
of
change
 of temperature of the thermal zone. Ideally, the thermal sensor
drivers
 are supposed to implement the callback. If they don't, the
thermal
 framework calculated the trend by comparing the previous and the
current
 temperature values.
 
-5.2:get_thermal_instance:
+5.2. get_thermal_instance
+-------------------------
+
 This function returns the thermal_instance corresponding to a
given
 {thermal_zone, cooling_device, trip_point} combination. Returns
NULL
 if such an instance does not exist.
 
-5.3:thermal_notify_framework:
+5.3. thermal_notify_framework
+-----------------------------
+
 This function handles the trip events from sensor drivers. It
starts
 throttling the cooling devices according to the policy
configured.
 For CRITICAL and HOT trip points, this notifies the respective
drivers,
@@ -609,12 +768,15 @@ and does actual throttling for other trip
points i.e ACTIVE and PASSIVE.
 The throttling policy is based on the configured platform data;
if
no
 platform data is provided, this uses the step_wise throttling
policy.
 
-5.4:thermal_cdev_update:
+5.4. thermal_cdev_update
+------------------------
+
 This function serves as an arbitrator to set the state of a
cooling
 device. It sets the cooling device to the deepest cooling state
if
 possible.
 
-6. thermal_emergency_poweroff:
+6. thermal_emergency_poweroff
+=============================
 
 On an event of critical trip temperature crossing. Thermal
framework
 allows the system to shutdown gracefully by calling
orderly_poweroff().
diff --git a/Documentation/thermal/x86_pkg_temperature_thermal
b/Documentation/thermal/x86_pkg_temperature_thermal.rst
similarity index 80%
rename from Documentation/thermal/x86_pkg_temperature_thermal
rename to Documentation/thermal/x86_pkg_temperature_thermal.rst
index 17a3a4c0a0ca..f134dbd3f5a9 100644
--- a/Documentation/thermal/x86_pkg_temperature_thermal
+++ b/Documentation/thermal/x86_pkg_temperature_thermal.rst
@@ -1,19 +1,23 @@
+===================================
 Kernel driver: x86_pkg_temp_thermal
-===================
+===================================
 
 Supported chips:
+
 * x86: with package level thermal management
+
 (Verify using: CPUID.06H:EAX[bit 6] =1)
 
 Authors: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.co
m>
 
 Reference
----
+---------
+
 Intel® 64 and IA-32 Architectures Software Developer’s Manual
(Jan,
2013):
 Chapter 14.6: PACKAGE LEVEL THERMAL MANAGEMENT
 
 Description
----------
+-----------
 
 This driver register CPU digital temperature package level
sensor as
a thermal
 zone with maximum two user mode configurable trip points. Number
of
trip points
@@ -25,23 +29,27 @@ take any action to control temperature.
 Threshold management
 --------------------
 Each package will register as a thermal zone under
/sys/class/thermal.
-Example:
-/sys/class/thermal/thermal_zone1
+
+Example::
+
+	/sys/class/thermal/thermal_zone1
 
 This contains two trip points:
+
 - trip_point_0_temp
 - trip_point_1_temp
 
 User can set any temperature between 0 to TJ-Max temperature.
Temperature units
-are in milli-degree Celsius. Refer to
"Documentation/thermal/sysfs-
api.txt" for
+are in milli-degree Celsius. Refer to
"Documentation/thermal/sysfs-
api.rst" for
 thermal sys-fs details.
 
 Any value other than 0 in these trip points, can trigger thermal
notifications.
 Setting 0, stops sending thermal notifications.
 
-Thermal notifications: To get kobject-uevent notifications, set
the
thermal zone
-policy to "user_space". For example: echo -n "user_space" >
policy
-
-
+Thermal notifications:
+To get kobject-uevent notifications, set the thermal zone
+policy to "user_space".
 
+For example::
 
+	echo -n "user_space" > policy
diff --git a/MAINTAINERS b/MAINTAINERS
index d9e214f68e52..b2254bc8e495 100644
--- a/MAINTAINERS
+++ b/MAINTAINERS
@@ -15687,7 +15687,7 @@ M:	Viresh Kumar <viresh.kumar@lina
ro.o  
rg>  
 M:	Javi Merino [off-list ref]
 L:	linux-pm@vger.kernel.org
 S:	Supported
-F:	Documentation/thermal/cpu-cooling-api.txt
+F:	Documentation/thermal/cpu-cooling-api.rst
 F:	drivers/thermal/cpu_cooling.c
 F:	include/linux/cpu_cooling.h
 
diff --git a/include/linux/thermal.h b/include/linux/thermal.h
index 15a4ca5d7099..681047f8cc05 100644
--- a/include/linux/thermal.h
+++ b/include/linux/thermal.h
@@ -251,7 +251,7 @@ struct thermal_bind_params {
 	 * platform characterization. This value is relative to
the
 	 * rest of the weights so a cooling device whose weight
is
 	 * double that of another cooling device is twice as
-	 * effective. See Documentation/thermal/sysfs-api.txt
for
more
+	 * effective. See Documentation/thermal/sysfs-api.rst
for
more
 	 * information.
 	 */
 	int weight;
@@ -259,7 +259,7 @@ struct thermal_bind_params {
 	/*
 	 * This is a bit mask that gives the binding relation
between this
 	 * thermal zone and cdev, for a particular trip point.
-	 * See Documentation/thermal/sysfs-api.txt for more
information.
+	 * See Documentation/thermal/sysfs-api.rst for more
information.
 	 */
 	int trip_mask;
   

Thanks,
Mauro
_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help