Thread (1 message) 1 message, 1 author, 2018-12-18

Re: [PATCH v3 1/6] dt-bindings: ap806: add the cluster clock node in the syscon file

From: Gregory CLEMENT <gregory.clement@bootlin.com>
Date: 2018-12-18 15:46:31
Also in: linux-clk, linux-devicetree, lkml

Hi Rob,
 
 On lun., déc. 17 2018, Rob Herring [off-list ref] wrote:
On Sun, Dec 16, 2018 at 10:41:42AM +0100, Gregory CLEMENT wrote:
quoted
Document the device tree binding for the cluster clock controllers found
in the Armada 7K/8K SoCs.

Signed-off-by: Gregory CLEMENT <gregory.clement@bootlin.com>
---
 .../arm/marvell/ap806-system-controller.txt   | 22 +++++++++++++++++++
 1 file changed, 22 insertions(+)
diff --git a/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt b/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt
index 3fd21bb7cb37..8f281816a6b8 100644
--- a/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt
+++ b/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt
@@ -136,3 +136,25 @@ ap_syscon1: system-controller@6f8000 {
 		#thermal-sensor-cells = <1>;
 	};
 };
+
+Cluster clocks:
+---------------
+
+Device Tree Clock bindings for cluster clock of AP806 Marvell. Each
+cluster contain up to 2 CPUs running at the same frequency.
+
+Required properties:
+- compatible: must be  "marvell,ap806-cpu-clock";
+- #clock-cells : should be set to 1.
+- clocks : shall be the input parents clock phandle for the clock.
+
+ap_syscon1: system-controller@6f8000 {
+	compatible = "syscon", "simple-mfd";
+	reg = <0x6f8000 0x1000>;
+
+	cpu_clk: clock-cpu {
There's not a register address range you can use even if Linux happens 
to not need it (currently)?
We can add an optional reg property if you want, but the whole point of
this, is to be able to ensure the compatibility. Indeed, we have now
enough experience to know that the information we have from the
datasheet is incomplete. And when we start to deal with an IP calling
"system controller", then we can expect a mix between all the registers.
There's already a clock node under this syscon? Are they really separate 
sub-blocks?
Actually the other clock node (marvell,ap806-clock) is under the other
syscon: system controller 0 with gpio and pinctrl, whereas this one
(marvell,ap806-cpu-clock), is under system controller 1 with thermal.

Gregory
quoted
+		compatible = "marvell,ap806-cpu-clock";
+		clocks = <&ap_clk 0>, <&ap_clk 1>;
+		#clock-cells = <1>;
+	};
+};
-- 
2.19.2
-- 
Gregory Clement, Bootlin
Embedded Linux and Kernel engineering
http://bootlin.com

_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel