[PATCH V2 7/8] dts: fsl: add imx7ulp evk support
From: aisheng.dong@nxp.com (A.s. Dong)
Date: 2018-10-26 13:52:13
Also in:
linux-devicetree
-----Original Message----- From: Sascha Hauer [mailto:s.hauer at pengutronix.de] Sent: Friday, October 26, 2018 6:57 PM
[...]
On Wed, Oct 24, 2018 at 08:14:01AM +0000, A.s. Dong wrote:quoted
quoted
-----Original Message----- From: Fabio Estevam [mailto:festevam at gmail.com] Sent: Wednesday, October 24, 2018 12:26 AM[...]quoted
On Tue, Oct 23, 2018 at 11:42 AM A.s. Dong [off-list ref]wrote:quoted
quoted
quoted
I'm a bit hesitate to do that as the driver already supports it. There's no extra effort to use it. And we probably could take ULP as a special case to test generic binding rather then simply drop it and drop driver features. Once we get objection from users later, we still cansimply fallback as there's still only official boards using it. We had this same discussion some months ago when we were reviewing i.MX8 support. I don't see the value in doing pinctrl differently on i.MX7ULP.I thought the situation is different as ULP actually already supports generic binding before that discussion.quoted
quoted
Last, it's not correct that there's not only one method for all i.MX devices. MX23/28 are different ones and ULP is more like MX23/28. And I saw no objections from users for MX23/28.Yes, but these are legacy platforms. For new ones, we should try to keep consistency, just like we discussed during i.MX8 review.So the question is whether it's necessary to switch generic binding back to the legacy one for ULP. Personally I'm not strongly against this, but I need some confirmation from Shawn and Sascha. Shawn & Sascha, would you make a judgement call? If you also strongly request that, I will try to make it patch to test Linus W. Hopefully our agreement could satisfy Linus W.For consistency reasons I vote for using the legacy binding for i.MX7ulp aswell.
Thanks for the feedback. Will try to cook a patch to send to Linus W. Regards Dong Aisheng
Sascha -- Pengutronix e.K. | | Industrial Linux Solutions | https://emea01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww. pengutronix.de%2F&data=02%7C01%7Caisheng.dong%40nxp.com%7C74 a0d2aca1cf432528a608d63b31c614%7C686ea1d3bc2b4c6fa92cd99c5c3016 35%7C0%7C0%7C636761482309424341&sdata=Mi5aWJmBcYI3xZLsEdj O%2BQ7JUKZS1EzXuW%2Bd2WBJtek%3D&reserved=0 | Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |